We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in \cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $\pm \hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, we demonstrate that such diffraction pulses can remain efficient on atoms with non zero velocity, such as in a gravimeter, when modulating the frequency of one of the two Raman laser sources. We use such pulses to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This reduces the technical requirements and would allow the realization of a simple atomic gravimeter. We demonstrate a sensitivity of $1.2\times10^{-7}g$ per shot.
We present the construction of the two-state model of the atomic gravimeter and the associated Kalman recursion to estimate gravity acceleration from atomic gravimeter. We find the Kalman estimator greatly improve the precision of estimates in short term by removing the white phase noise. The residual noise of the estimates follows 0.13 muGal/\sqrt{s} for up to more than 100 s and highlights a precision of 0.34 muGal at the measuring time of a single sample, even with no seismometer correction.
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the…
We present a precision gravimeter based on coherent Bragg diffraction of freely falling cold atoms. Traditionally, atomic gravimeters have used stimulated Raman transitions to separate clouds in momentum space by driving transitions between two internal atomic states. Bragg interferometers utilize only a single internal state, and can therefore be less susceptible to environmental perturbations. Here we show that atoms extracted from a magneto-optical trap using an accelerating optical lattice are a suitable source for a Bragg atom interferometer, allowing efficient beamsplitting and subsequen…
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.
We present a new scheme of compact atomic gravimeter based on atom interferometry. Atoms are maintained against gravity using a sequence of coherent accelerations performed by the Bloch oscillations technique. We demonstrate a sensitivity of 4.8$\times 10^{-8}$ with an integration time of 4 min. Combining this method with an atomic elevator allows to measure the local gravity at different positions in the vacuum chamber. This method can be of relevance to improve the measurement of the Newtonian gravitational constant $G$.
This work establishes a high-precision relativistic theoretical model: start from studying finite speed of light effect based on a coordinate transformation, and further extend the research methods to analyze the overall relativistic effects. This model promotes the development of testing General Relativity with atomic interferometry.
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to change…
In high-precision atomic gravimeters, a rest mass is needed to provide a gravity reference, which is typically the retro-reflecting mirror of the Raman laser beams that addresses the two hyperfine ground states of the specific free-falling atomic test mass. We constructed a compact active feedback control system for the retro-reflecting mirror that provides vibration isolation in the vertical axis as well as two rotation stabilization in the horizontal plane. The active feedback control provides vertical vibration reduction of up to a factor of 300 in the frequency range of 0.03 to 10 Hz and t…
We characterize the performance of a gravimeter and a gravity gradiometer based on the $^{1}$S$_{0}$-$^3$P$_0$ clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of $1.7\times10^{-5}$, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiome…
A single-seed, module-based compact laser system is demonstrated on a transportable $^{87}\text{Rb}$-based high-precision atomic gravimeter. All the required laser frequencies for the atom interferometry are provided by free-space acousto-optic modulators (AOMs) and resonant electro-optic phase modulators (EOMs). The optical phase-locked loop between the two optical paths derived from the same laser provides an easy frequency manipulation between two laser frequencies separated by the hyperfine frequency of 6.835 GHz using an AOM and an EOM, respectively. Our scheme avoids parasite Raman trans…
We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial posit…
Mobile gravimetry is important in metrology, navigation, geodesy, and geophysics. Atomic gravimeters could be among the most accurate mobile gravimeters, but are currently constrained by being complex and fragile. Here, we demonstrate a mobile atomic gravimeter, measuring tidal gravity variations in the laboratory as well as surveying gravity in the field. The tidal gravity measurements achieve a sensitivity of 37 $μ$Gal/$\sqrt{\rm Hz}$ and a long-term stability of better than 2 $μ$Gal, revealing ocean tidal loading effects and recording several distant earthquakes. We survey gravity in the Be…
Wavefront aberrations are one of the largest uncertainty factors in present atom interferometers. We present a detailed numerical and experimental analysis of this effect based on measured aberrations from optical windows. By placing windows into the Raman beam path of our atomic gravimeter, we verify for the first time the induced bias in very good agreement with theory. Our method can be used to reduce the uncertainty in atomic gravimeters by one order of magnitude resulting in an error of less than $3\times 10^{-10}\,g$ and it is suitable in a wide variety of atom interferometers with therm…
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the regime ( ). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the Gravimetric Atom Interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step size dependent magnetic field measurement uncertainty, present vector light shift (VLS) and tensor light shift (TLS) induced magnetic field mea…
One of the major limitations of atomic gravimeters is represented by the vibration noise of the measurement platform, which cannot be distinguished from the relevant acceleration signal. We demonstrate a new method to perform an atom interferometry measurement of the gravitational acceleration without any need for a vibration isolation system or post-corrections based on seismometer data monitoring the residual accelerations at the sensor head. With two subsequent Ramsey interferometers, we measure the velocity variation of freely falling cold atom samples, thus determining the gravitational a…
We report on the first atom interferometer based on Bragg diffraction in a fountain of alkaline-earth atoms, namely $^{88}$Sr. We demonstrate large momentum transfer to the atoms up to eight photon recoils and the use of the interferometer as a gravimeter with a sensitivity $δg/g=4\times 10^{-8}$. Thanks to the special characteristics of strontium atoms for precision measurements, this result opens a new way for experiments in fundamental and applied physics.
We develop a versatile theoretical approach to the study of cold-atom diffractive scattering from light-field gratings by combining calculations of the optical near-field, generated by evanescent waves close to the surface of periodic nanostructured arrays, together with advanced atom wavepacket propagation on this optical potential.
Atom-surface interactions can significantly modify the intensity and phase of atom de Broglie waves diffracted by a silicon nitride grating. This affects the operation of a material grating as a coherent beam splitter. The phase shift induced by diffraction is measured by comparing the relative phases of serveral interfering paths in a Mach-Zehnder Na atom interferometer formed by three material gratings. The values of the diffraction phases are consistent with a simple model which includes a van der Waals atom-surface interaction between the Na atoms and the silicon nitride grating bars.
In atom optics a material structure is commonly regarded as an amplitude mask for atom waves. However, atomic diffraction patterns formed using material gratings indicate that material structures also operate as phase masks. In this study a well collimated beam of sodium atoms is used to illuminate a silicon nitride grating with a period of 100 nm. During passage through the grating slots atoms acquire a phase shift due to the van der Waals interaction with the grating walls. As a result the relative intensities of the matter-wave diffraction peaks deviate from those expected for a purely abso…
Atomic sensors employing cold-atom technology enable unprecedented accuracy and resolution for next generation atomic clocks, magnetometers, gravimeters, and gyroscopes. To date, however, the size and complexity of cold atom systems have prevented their deployment in practical applications outside of large research laboratories. Here we demonstrate a low power, palm-top, and fully integrated cold atom system that functions as an atomic clock with a stability of 2 parts in 10^11 at 1s. This work demonstrates the feasibility of developing compact, robust, and portable devices based on laser cool…
We report on a new technique to split an atomic beam coherently with an easily adjustable splitting angle. In our experiment metastable helium atoms in the |{1s2s}^3S_1 M=1> state diffract from a polarization gradient light field formed by counterpropagating σ^+ and σ^- polarized laser beams in the presence of a homogeneous magnetic field. In the near-adiabatic regime, energy conservation allows the resonant exchange between magnetic energy and kinetic energy. As a consequence, symmetric diffraction of |M=0> or |M=-1> atoms in a single order is achieved, where the order can be chosen freely by…
Quantum interference is shown to deliver a means of regulating the diffraction pattern of a thermal atomic beam interacting with two standing wave electric fields. Parameters have been identified to enhance the diffraction probability of one momentum component over the others, with specific application to Rb atoms.
We provide a comprehensive study of atomic Raman and Bragg diffraction when coupling to a pair of counterpropagating light gratings (double diffraction) or to a single one (single diffraction) and discuss the transition from one case to the other in a retroreflective geometry as the Doppler detuning changes. In contrast to single diffraction, double Raman loses its advantage of high diffraction efficiency for short pulses and has to be performed in a Bragg-type regime. Moreover, the structure of double diffraction leads to further limitations for broad momentum distributions on the efficiency …
We apply a Bloch-bands approach to the analysis of pulsed optical standing wave diffractive elements in optics and interferometry with ultracold atoms. We verify our method by comparison to a series of experiments with Bose-Einstein condensates. The approach provides accurate Rabi frequencies for diffraction pulses and is particularly useful for the analysis and control of diffraction phases, an important systematic effect in precision atom interferometry. Utilizing this picture, we also demonstrate a method to determine atomic band structure in an optical lattice through a measurement of phas…
We present a local measurement of gravity combining Bloch oscillations and atom interferometry. With a falling distance of 0.8 mm, we achieve a sensitivity of 2x10-7 g with an integration time of 300 s. No bias associated with the Bloch oscillations has been measured. A contrast decay with Bloch oscillations has been observed and attributed to the spatial quality of the laser beams. A simple experimental configuration has been adopted where a single retro-reflected laser beam is performing atoms launch, stimulated Raman transitions and Bloch oscillations. The combination of Bloch oscillations …
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in future experiments based on large momentum beam splitters. In this article, we tackle this issue by using a deformable mirror to control actively the laser wavefronts in atom interferometry. In particul…
In a retroreflective scheme atomic Raman diffraction adopts some of the properties of Bragg diffraction due to additional couplings to off-resonant momenta. As a consequence, double Raman diffraction has to be performed in a Bragg-type regime. Taking advantage of this regime, double Raman allows for resonant higher-order diffraction. We study theoretically the case of third-order diffraction and compare it to first order as well as a sequence of first-order pulses giving rise to the same momentum transfer as the third-order pulse. In fact, third-order diffraction constitutes a competitive tool…
IIn this paper we demonstrate a new scheme for Raman transitions which realize a symmetric momentum-space splitting of $4 \hbar k$, deflecting the atomic wave-packets into the same internal state. Combining the advantages of Raman and Bragg diffraction, we achieve a three pulse state labelled interferometer, intrinsically insensitive to the main systematics and applicable to all kind of atomic sources. This splitting scheme can be extended to $4N \hbar k$ momentum transfer by a multipulse sequence and is implemented on a $8 \hbar k$ interferometer. We demonstrate the area enhancement by measur…
A brief review of the manifestations of classical chaos observed in atomic systems is presented. Particular attention is paid to the analysis of atomic spectra by periodic orbit-type theories. For diamagnetic non-hydrogenic Rydberg atoms, the dynamical explanation for observed spectral features has been disputed. By building on our previous work on the photoabsorption spectrum, we show how, by the addition of diffractive terms, the spectral fluctuations in the energy level spectrum of general Rydberg atoms can be obtained with remarkable precision from the Gutzwiller trace formula. This provid…
Bragg diffraction of an atomic wave packet in a retroreflective geometry with two counterpropagating optical lattices exhibits a light shift induced phase. We show that the temporal shape of the light pulse determines the behavior of this phase shift: In contrast to Raman diffraction, Bragg diffraction with Gaussian pulses leads to a significant suppression of the intrinsic phase shift due to a scaling with the third power of the inverse Doppler frequency. However, for box-shaped laser pulses, the corresponding shift is twice as large as for Raman diffraction. Our results are based on approxim…
We demonstrate a proof-of-principle of direct Earth gravity gradient measurement with an atom interferometer-based gravity gradiomter using a single proof mass of cold 87 rubidium atoms. The atomic gradiometer is implemented in the so-called double-loop configuration, hence providing a direct gravity gradient dependent phase shift insensitive do DC acceleration and constant rotation rate. The atom interferometer (AI) can be either operated as a gravimeter or a gradiomter by simply adding an extra Raman $π$-pulse. We demonstrate gravity gradient measurements first using a vibration isolation pl…
We report a novel experimental technique for the comparison of ionization processes in ultrafast laser pulses irrespective of pulse ellipticity. Multiple ionization of xenon by 50 fs 790 nm, linearly and circularly polarized laser pulses is observed over the intensity range 10 TW/cm^2 to 10 PW/cm^2 using Effective Intensity Matching (EIM), which is coupled with Intensity Selective Scanning (ISS) to recover the geometry-independent probability of ionization. Such measurements, made possible by quantifying diffraction effects in the laser focus, are compared directly to theoretical predictions o…
We present a simple method to include the effects of diffraction into the description of a light-atomic ensemble quantum interface in the context of collective variables. Carrying out a scattering calculation we single out the purely geometrical effect. We apply our method to the experimentally relevant case of Gaussian shaped atomic samples stored in single beam optical dipole traps and probed by a Gaussian beam. We derive analytical scaling relations for the effect of the interaction geometry and compare our findings to results from 1-dimensional models of light propagation.
We have studied atomic diffraction at normal incidence from an evanescent standing wave with a high resolution using velocity selective Raman transitions. We have observed up to 3 resolved orders of diffraction, which are well accounted for by a scalar diffraction theory. In our experiment the transverse coherence length of the source is greater than the period of the diffraction grating.
The best clocks to date control the atomic motion by trapping the sample in an optical lattice and then interrogate the atomic transition by shining on these atoms a distinct laser of controlled frequency. In order to perform both tasks simultaneously and with the same laser field, we propose to use instead the levitation of a Bose-Einstein condensate through multiple-wave atomic interferences. The levitating condensate experiences a coherent localization in momentum and a controlled diffusion in altitude. The sample levitation is bound to resonance conditions used either for frequency or for …
In atomic systems, clock states feature a zero projection of the total angular momentum and thus a low sensitivity to magnetic fields. This makes them widely used for metrological applications like atomic fountains or gravimeters. Here, we show that a mixture of two such non-magnetic states still display magnetic dipole-dipole interactions. Using high resolution spectroscopy of a planar gas of $^{87}$Rb atoms with a controlled in-plane shape, we explore the effective isotropic and extensive character of these interactions and demonstrate their tunability. Our measurements set strong constraint…
We investigate the atomic diffractions of a Bose-Einstein condensate in quantized light fields. Situations in which the light fields are in number states or coherent states are studied theoretically. Analytical derivation and numerical calculation are carried out to simulate the dynamics of the atomic motion. In condition that atoms are scattered by light in the number states with imbalanced photon number distribution, the atomic transitions between different momentum modes would sensitively depend on the transition order and the photon number distribution. The number-state-nature of the light…
Time-resolved femtosecond x-ray diffraction patterns from laser-excited molecular iodine are used to create a movie of intramolecular motion with time and space resolution of $30~$fs and $0.3$ Å. The high spatial fidelity is due to interference between the moving excitation and the static initial charge distribution. This x-ray interference has not been employed to image internal motion in molecules before. The initial state is used as the local oscillator for heterodyne amplification of the excited charge distribution to retrieve real-space movies of atomic motion on Ångstrom and femtosecond …
Laser frequency noise is a dominant noise background for the detection of gravitational waves using long-baseline optical interferometry. Amelioration of this noise requires near simultaneous strain measurements on more than one interferometer baseline, necessitating, for example, more than two satellites for a space-based detector, or two interferometer arms for a ground-based detector. We describe a new detection strategy based on recent advances in optical atomic clocks and atom interferometry which can operate at long-baselines and which is immune to laser frequency noise. Laser frequency …
We present a theoretical justification for a method of extracting of supplementary information for the phase retrieval procedure taken from diffraction of fs-pulses from X-ray Free Electron Laser facilities. The approach is based on numerical simulation of the dynamics of the electron density in the crystal composed of different atoms in the unit cell, namely a bi-atomic crystal containing heavy and light atoms. It is shown that evaluation of diffraction intensities measured by means of different values of XFEL pulse parameters enables to find absolute values of structure factors for both type…