将LTP温度诊断扩展到LISA频段:第一批结果

Extension of the LTP temperature diagnostics to the LISA band: first results

J Sanjuan, J Ramos-Castro, A Lobo

摘要:

在LTP中需要高分辨率的温度测量,即,10 uK/sqrt(Hz),从1 mHz到30 mHz。这已经通过晶闸管和适当的低噪声电子器件实现。然而,LISA感兴趣的频率范围下降到0.1 mHz。在0.1 mHz左右的频率的温度传感器和相关的电子器件的性能进行了调查。示出了温度测量系统的理论限制和测试它们的实际地面限制,表明即使在0.1 mHz左右的频率和10 uK/sqrt(Hz)的幅度水平下,在晶闸管中也没有观察到1/f噪声。

英文摘要:

High-resolution temperature measurements are required in the LTP, i.e., 10 uK/sqrt(Hz) from 1 mHz to 30 mHz. This has been already accomplished with thermistors and a suitable low noise electronics. However, the frequency range of interest for LISA goes down to 0.1 mHz. Investigations on the performance of temperature sensors and the associated electronics at frequencies around 0.1 mHz have been performed. Theoretical limits of the temperature measurement system and the practical on-ground limitations to test them are shown demonstrating that 1/f noise is not observed in thermistors even at frequencies around 0.1 mHz and amplitude levels of 10 uK/sqrt(Hz).