我们报道了一个698 nm主从半导体激光系统的建立和表征,用于探测一维光晶格中锶原子的1 S 0 - 3 P0时钟跃迁。使用飞秒光纤梳作为传输振荡器,相对于具有1Hz线宽的超稳定657 nm二极管激光器,测量了激光系统的大约100 Hz的线宽。该激光器已被用来测量磁感应1 S 0 - 3 P0时钟跃迁在88 Sr的线宽为165 Hz已被观察到。转移振荡器方法在两个二极管激光器之间提供虚拟拍频信号,该虚拟拍频信号已经用于将698 nm激光器锁相到657 nm处的1 Hz线宽激光器,将其稳定性转移到698 nm激光器系统。
英文摘要:
We report on the setup and characterization of a 698 nm master-slave diode laser system to probe the 1S0-3P0 clock transition of strontium atoms confined in a one-dimensional optical lattice. A linewidth in the order of around 100 Hz of the laser system has been measured with respect to an ultrastable 657 nm diode laser with 1 Hz linewidth using a femtosecond fiber comb as transfer oscillator. The laser has been used to measure the magnetically induced 1S0-3P0 clock transition in 88Sr where a linewidth of 165 Hz has been observed. The transfer oscillator method provides a virtual beat signal between the two diode lasers that has been used to phase lock the 698 nm laser to the 1 Hz linewidth laser at 657 nm, transferring its stability to the 698 nm laser system.
We present the first characterization of the spectral properties of superradiant light emitted from the ultra-narrow, 1 mHz linewidth optical clock transition in an ensemble of cold $^{87}$Sr atoms. Such a light source has been proposed as a next-generation active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. By comparing the frequency of our superradiant source to that of a state-of-the-art cavity-stabilized laser and optical lattice clock, we observe a fractional Allan deviation of $6.7(1)\time…
Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with dead time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise of the laser interrogating the atomic transition. Despite recent advances in optical clock stability achieved by improving laser coherence, the Dick effect has continually limited optical clock performance. Here we implement a robust solutio…
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability b…
We demonstrate single-atom resolved imaging with a survival probability of $0.99932(8)$ and a fidelity of $0.99991(1)$, enabling us to perform repeated high-fidelity imaging of single atoms in tweezers for thousands of times. We further observe lifetimes under laser cooling of more than seven minutes, an order of magnitude longer than in previous tweezer studies. Experiments are performed with strontium atoms in $813.4~\text{nm}$ tweezer arrays, which is at a magic wavelength for the clock transition. Tuning to this wavelength is enabled by off-magic Sisyphus cooling on the intercombination li…
We realize a two-stage, hexagonal pyramid magneto-optical trap (MOT) with strontium, and demonstrate loading of cold atoms into cavity-enhanced 1D and 2D optical lattice traps, all within a single compact assembly of in-vacuum optics. We show that the device is suitable for high-performance quantum technologies, focusing especially on its intended application as a strontium optical lattice clock. We prepare $2\times 10^4$ spin-polarized atoms of $^{87}$Sr in the optical lattice within 500 ms; we observe a vacuum-limited lifetime of atoms in the lattice of 27 s; and we measure a background DC e…
High accuracy correction of blackbody radiation shift in an optical lattice clock
我们已经确定了黑体辐射在锶中的$5s^2$ $^1$ S $_0$ -- $5s5p$ $^3$ P $_0$时钟跃迁上引起的频移。以前它的不确定性限制了锶晶格钟的不确定性为$1\times10^{-16}$。现在,与黑体辐射位移校正相关的不确定性转化为室温下的$5\times 10^{-18}$相对频率不确定性。我们的评估是基于两个时钟状态的差分直流极化率的测量和使用此值和其他原子属性的实验数据的动态贡献的建模。
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found…
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length $L$ over diameter $D$ $L/D>1$. Generally large $L$ helps to reduce thermal n…
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.
We have developed a universal method to form the reference signal for the stabilization of arbitrary atomic clocks based on Ramsey spectroscopy. Our approach uses an interrogation scheme of the atomic system with two different Ramsey periods and a specially constructed combined error signal (CES) computed by subtracting two error signals with the appropriate calibration factor. CES spectroscopy allows for perfect elimination of probe-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors and other imperfection…
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to on…
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of $(1-2)\times 10^{-17}$ Hz$^{-1/2}$ at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measuremen…
We outline new laser interferometer measurements to search for variation of the electromagnetic fine-structure constant $α$ and particle masses (including a non-zero photon mass). We propose a strontium optical lattice clock -- silicon single-crystal cavity interferometer as a novel small-scale platform for these new measurements. Multiple passages of a light beam inside an interferometer enhance the effects due to variation of the fundamental constants by the mean number of passages ($N_{\textrm{eff}} \sim 10^2$ for a large-scale gravitational-wave detector, such as LIGO, Virgo, GEO600 or TAM…
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usable levels with the current state of technology. Here we investigate the spectral properties and the stability of active clocks, including homogeneous and inhomogeneous broadening effects. We find tha…
We propose a new frequency standard based on a $4f^{14} 6s6p~ ^3\!P_0 - 4f^{13} 6s^2 5d ~(J=2)$ transition in neutral Yb. This transition has a potential for high stability and accuracy and the advantage of the highest sensitivity among atomic clocks to variation of the fine-structure constant $α$. We find its dimensionless $α$-variation enhancement factor to be $K=-15$, in comparison to the most sensitive current clock (Yb$^+$ E3, $K=-6$), and it is 18 times larger than in any neutral-atomic clocks (Hg, $K=0.8$). Combined with the unprecedented stability of an optical lattice clock for neutra…
The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidth. We present two ultrastable laser systems based on 48 cm long Fabry-Perot cavities made of ULE glass in horizontal and vertical configurations operating at 698 nm. Fractional frequency instability of the beat signal between two lasers reaches 1.6e-15 at the averaging time of 1 s. We experimentally characterized the contribution of the different noise sources (power fluctuations, residual amplitude modulation, the Doppler noise, sensitivity to the shock impact) and found that in o…
We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 a…