一种压电微泵的研制及应用

Development and Application of a Diaphragm Micro-Pump with Piezoelectric Device

H. K. Ma, B. R. Hou, H. Y. Wu, C. Y. Lin, J. J. Gao, M. C. Kou

摘要:

在本研究中,一种新型的薄,紧凑,重量轻的隔膜微型泵已成功地开发出驱动液体的振动的隔膜。双阀微型隔膜泵采用高精度数控机床在铝壳内加工而成,截面尺寸为5 mm × 8 mm。阀门和隔膜均由PDMS制成。压电装置的振动幅度产生振荡流,该振荡流可以通过改变隔膜的曲率来改变腔室容积。设计并实现了单微隔膜泵、等温流动开放系统和封闭液体冷却系统的性能测试实验装置。单向驱动微型隔膜泵的性能受单向阀、膜片、压电元件、腔室容积、输入电压和频率等参数的影响。在工作频率为70-180 Hz范围内,在零总泵压头下,本设计的实测最大流量为72 ml/min。

英文摘要:

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate the liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 5mm x 8mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow which may change the chamber volume by changing the curvature of a diaphragm. Several experimental set-ups for performance test in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system is designed and implemented. The performance of one-side actuating micro-diaphragm pump is affected by the design of check valves, diaphragm, piezoelectric device, chamber volume, input voltage and frequency. The measured maximum flow rate of present design is 72 ml/min at zero total pump head in the range of operation frequency 70-180 Hz.