辉光放电AES:脉冲元素分析和闪速解吸的方法学特性
Glow Discharge AES: Methodological Peculiarities of Pulse Element Analysis and Flash Desorption
摘要:
本文介绍了辉光放电AES的不同技术。在这样的调查中最重要的参数是:VHF场的功率,惰性气体的压力和易电离的添加剂,例如NaCl的浓度。这些参数的影响进行了研究。提出了一种高灵敏度的闪解吸方法,使调查的水解吸率从加湿样品的生物来源,即DNA和染色质。最小化检测限的方法被认为是分析仪器最重要的特性。如果任何被测元素的浓度与等于背景测量结果的三倍标准偏差的信号相关,则该浓度是可检测的。用氦的两条谱线λ=353.828nm,λ '= 344.759nm的吸收率估算了氦的电子温度,其T_c值为15000K。
英文摘要:
Different techniques of Glow Discharge AES are described in this paper. The most important parameters at such investigations are: the power of VHF-field, pressure of the inert gas and concentration of the easily ionizable additive, e.g. NaCl. The influences of these parameters were studied It is proposed a high sensitive flash desorption method, which enables investigation of the water desorption rate from humidified samples of biological origin, namely DNA and chromatin. The ways of minimizing of detection limit are considered as the most important characteristics of an analytical device. The concentration of any measured element is detectable if it correlates to the signal equal to tripled standard deviation of the results of background measurement. Electron temperature of the Helium has been evaluated by absorption rate at two lines of helium λ=353.828nm; λ'=344.759nm that was equal to T_c ~ 15000 K.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。