We report the realisation and preliminary study of a frequency standard using a fountain of laser cooled caesium atoms. Our apparatus uses a magneto-optical trap as a source of cold atoms and optical pumping to prepare the atoms in the correct state before they enter the microwave cavity.
The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of $20 \hbar k$ and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast compared to the commonly used scheme c…
A technique is demonstrated that allows free space atomic fountain clocks and interferometers to utilize optical cavity generated spin-squeezed states with over $390\,000$ ${}^{87}\text{Rb}$ atoms. Fluorescence imaging is used for population spectroscopy, after a free fall time of 4 milliseconds, to resolve a single-shot phase sensitivity of $814 (61)$ microradians, which is $5.8(0.6)$ decibels (dB) below the quantum projection limit. The dynamic range is observed to be 100 milliradians. When operating as a microwave atomic clock with $240\,000$ atoms at a 3.6 ms Ramsey time, a single-shot fra…
We use an atomic fountain clock to measure quantum scattering phase shifts precisely through a series of narrow, low-field Feshbach resonances at average collision energies below $1\,μ$K. Our low spread in collision energy yields phase variations of order $\pm π/2$ for target atoms in several $F,m_F$ states. We compare them to a theoretical model and establish the accuracy of the measurements and the theoretical uncertainties from the fitted potential. We find overall excellent agreement, with small statistically significant differences that remain unexplained.
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the fi…
We numerically demonstrate atomic Fabry-Perot resonances for a pulsed interacting Bose-Einstein condensate (BEC) source transmitting through double Gaussian barriers. These resonances are observable for an experimentally-feasible parameter choice, which we determined using a previously-developed analytical model for a plane matter-wave incident on a double rectangular barrier system. By simulating an effective one-dimensional Gross-Pitaevskii equation, we investigate the effect of atom number, scattering length, and BEC momentum width on the resonant transmission peaks. For $^{85}$Rb atomic so…
Atomic clocks can measure the gravitational redshift predicted by general relativity with great accuracy and for height differences as little as 1 cm. All existing experiments, however, involve the comparison of two independent clocks at different locations rather than a single clock in a delocalized quantum superposition. Here we present an interferometry scheme employing group-II-type atoms, such as Sr or Yb, capable of measuring the gravitational time dilation in a coherent superposition of atomic wave packets at two different heights. In contrast to other recent proposals, there is no need…
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using two caesium fountain clocks. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the…