RR间隔频谱、ECG信号和混叠
The RR interval spectrum, the ECG signal and aliasing
摘要:
可靠的频谱分析要求采样率至少是频率范围的两倍,否则分析将不可靠并受到混叠失真的困扰。RR采样不满足上述要求,因此其谱分析可能不可靠。为了证明混叠在RR谱分析中的可行性,我们做了一个实验,清楚地显示了混叠是如何发展的。在实验中,我们中的一个(A.G)在节拍器的帮助下保持他的高呼吸频率恒定超过5分钟。呼吸频率大于心率的一半。获得了非常准确的结果,并且很好地理解了由此产生的混叠。据我们所知,这是第一个在人类身上进行的这种受控实验。我们比较了RR频谱分析与ECG信号的频谱,从其中提取的RR间期。在RR分析频率(低于二分之一赫兹)的显着差异进行了观察。总之,我们建议研究的频谱分析的心电信号中的自由混叠频率范围。
英文摘要:
A reliable spectral analysis requires sampling rate at least twice as large as the frequency bound, otherwise the analysis will be unreliable and plagued with aliasing distortions. The RR samplings do not satisfy the above requirements and therefore their spectral analysis might be unreliable. In order to demonstrate the feasibility of aliasing in RR spectral analysis, we have done an experiment which have shown clearly how the aliasing was developed. In the experiments, one of us (A.G) had kept his high breathing rate constant with the aid of metronome for more than 5 minutes. The breathing rate was larger than one-half the heart rate. Very accurate results were obtained and the resulting aliasing well understood. To our best knowledge this is the first controlled experiment of this kind coducted on humans. We compared the RR spectral analysis with the spectrum of the ECG signals from which the RR intervals were extracted. In the significant for RR analysis frequencies (below one-half Hertz) significant differences were observed. In conclusion we recommend to study the spectral analysis of the ECG signal in the free of aliasing frequency range.