Recently, the last two modules (out of seven) of the ALICE High Momentum Particle Identification detector (HMPID) were assembled and tested. The full detector, after a pre-commissioning phase, has been installed in the experimental area, inside the ALICE solenoid, at the end of September 2006. In this paper we review the status of the ALICE/HMPID project and we present a summary of the series production of the CsI photo-cathodes. We describe the key features of the production procedure which ensures high quality photo-cathodes as well as the results of the quality assessment performed by means of a specially developed 2D scanner system able to produce a detailed map of the CsI photo-current over the entire photo-cathode surface.
Finally we present our recent R&D efforts toward the development of a novel generation of imaging Cherenkov detectors with the aim to identify, in heavy ions collisions, hadrons up to 30 GeV/c.
The ALICE HMPID (High Momentum Particle IDentification) detector has been designed to identify charged pions and kaons in the range 1 < p < 3 GeV/c and protons in the range 1.5 < p < 5 GeV/c. It consists of seven identical proximity focusing RICH (Ring Imaging Cherenkov) counters, covering in total 11 m2, which exploit large area MWPC equipped with CsI photocathodes for Cherenkov light imaging emitted in a liquid C6F14 radiator. The ALICE detector has been widely commissioned using cosmics and LHC beam from December 2007 until October 2008. During the cosmics data taking the HMPID detector col…
In this paper, we present recent progress in the development of hydrophobic silica aerogel as a Cherenkov radiator. In addition to the conventional method, the recently developed pin-drying method for producing high-refractive-index aerogels with high transparency was studied in detail. Optical qualities and large tile handling for crack-free aerogels were investigated. Sufficient photons were detected from high-performance aerogels in a beam test.
Two beamline Cherenkov detectors (Ckov-a,-b) support particle identification in the MICE beamline. Electrons and high-momentum muons and pions can be identified with good efficiency. We report on the Ckov-a,-b performance in detecting pions and muons with MICE Step I data and derive an upper limit on the pion contamination in the standard MICE muon beam.
The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a CsI coated Triple-Thick-GEM (CsI-TTGEM) with metallic or resistive electrodes. We will present results from the laboratory studies as well as preliminary results of beam tests of a RICH detector prototype consisting of a CaF2 radiator coupled to a 10x10 cm2 CsI-TTGEM equipped with a pad readout and GASSIPLEX-based front-end electronics. With such a prototype …
In view of Run 4 at the LHC, presently scheduled from 2029 onwards, ALICE is pursuing several upgrades to further extend its physics reach. In order to improve heavy-flavor hadron and dielectron measurements which rely on secondary vertexing, a reduction of the material budget of the innermost layers of the Inner Tracking System is needed. This can be achieved with bent pixel sensors, arranged in half-cylinder shapes with integrated power lines and data buses, allowing to get rid of most of the supporting structure and of the water cooling. Moreover, a new Forward Calorimeter (FoCal), covering…
ALICE (A Large Ion Collider Experiment) experiment at CERN LHC is designed to study the properties of the Quark-Gluon Plasma (QGP) in heavy-ion collisions. In 2019-2020 the upgrade of CERN LHC will increase the luminosity and the collision rate beyond the design parameters of the current ALICE setup. To be able to benefit from the improved performance of the LHC, ALICE will upgrade several of its key detector systems including the Fast Interaction Trigger (FIT) [2]. FIT is designed to provide the functionality of the old forward detectors while retaining or even improving their performance. It…
The paper reviews recent progress in particle identification methods. A survey of motivations and requirements for particle identification in various experimental environments is followed by the main emphasis, which is on the recent development of Cherenkov counters, from upgrades of existing devices to a novel focusing radiator concept and new photon detectors. The impact of including a precise measurement of the time of arrival of Cherenkov photons to increase the kinematical region over which particle identification can be performed is discussed. The progress in dedicated time-of-flight cou…
The Inner Tracking System (ITS) is the key ALICE detector for the study of heavy flavour production at LHC. Heavy flavor can be studied via the identification of short-lived hadrons containing heavy quarks which have a mean proper decay length in the order of 100-300 $μ$m. To accomplish this task, the ITS is composed of six cylindrical layers of silicon detectors (two pixel, two drift and two strip) with a radial coverage from 3.9 to 43 cm and a material budget of 1.1% X0 per layer. %In particular, the properties of the two innermost layers define the ITS performance in measuring the displaced…
While spatial dose conformity delivered to a target volume has been pushed to its practical limits with advanced treatment planning and delivery, investigations in novel temporal dose delivery are unfolding new mechanisms. Recent advances in ultra-high dose radiotherapy, abbreviated as FLASH, indicate the potential for reduction in healthy tissue damage while preserving tumor control. FLASH therapy relies on very high dose rate of > 40Gy/sec with sub-second temporal beam modulation, taking a seemingly opposite direction from the conventional paradigm of fractionated therapy. FLASH brings uniqu…
This study presents the advancement in hydrophobic silica aerogel development for use as Cherenkov radiators and muonium production targets. These devices are scheduled for use in several particle- and nuclear-physics experiments that are planned in the near future at the Japan Proton Accelerator Research Complex. Our conventional method to produce aerogel tiles with an intermediate index of refraction of approximately 1.05 is extended so that we can now produce aerogel tiles with lower indices of refraction (i.e., 1.03-1.04) and higher indices of refraction (i.e., 1.075-1.08); each with excel…
This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward end cap of the Belle II detector. The proximity-focusing A-RICH system is especially designed to identify charged kaons and pions. The refractive index of the installed aerogel Cherenkov radiators is approximately 1.05, and we aim for a separation capability exceeding 4$σ$ at momenta up to 4 GeV/$c$. Large-area aerogel tiles (over 18 $\times $ 18 $\times $ 2 …