We present a method for producing sub-100 fs electron bunches that are suitable for single-shot ultrafast electron diffraction experiments in the 100 keV energy range. A combination of analytical results and state-of-the-art numerical simulations show that it is possible to create 100 keV, 0.1 pC, 20 fs electron bunches with a spotsize smaller than 500 micron and a transverse coherence length of 3 nm, using established technologies in a table-top set-up. The system operates in the space-charge dominated regime to produce energy-correlated bunches that are recompressed by established radio-frequency techniques. With this approach we overcome the Coulomb expansion of the bunch, providing an entirely new ultrafast electron diffraction source concept.
We demonstrate compression of 95 keV, space-charge-dominated electron bunches to sub-100 fs durations. These bunches have sufficient charge (200 fC) and are of sufficient quality to capture a diffraction pattern with a single shot, which we demonstrate by a diffraction experiment on a polycrystalline gold foil. Compression is realized by means of velocity bunching as a result of a velocity chirp, induced by the oscillatory longitudinal electric field of a 3 GHz radio-frequency cavity. The arrival time jitter is measured to be 80 fs.
Cold atom electron sources are a promising alternative to traditional photocathode sources for use in ultrafast electron diffraction due to greatly reduced electron temperature at creation, and the potential for a corresponding increase in brightness. Here we demonstrate single-shot, nanosecond electron diffraction from monocrystalline gold using cold electron bunches generated in a cold atom electron source. The diffraction patterns have sufficient signal to allow registration of multiple single-shot images, generating an averaged image with significantly higher signal-to-noise ratio than obt…
X-ray free electron lasers (XFELs) generate sequences of ultra-short, spatially coherent pulses of x-ray radiation. We propose the diffraction focusing spectrometer (DFS), which is able to measure the whole energy spectrum of the radiation of a single XFEL pulse with an energy resolution of $ΔE/E\approx 2\times 10^{-6}$. This is much better than for most modern x-ray spectrometers. Such resolution allows one to resolve the fine spectral structure of the XFEL pulse. The effect of diffraction focusing occurs in a single crystal plate due to dynamical scattering, and is similar to focusing in a P…
The Single Particles, Clusters and Biomolecules (SPB) instrument at the European XFEL is located behind the SASE1 undulator, and aims to support imaging and structure determination of biological specimen between about 0.1 micrometer and 1 micrometer size. The instrument is designed to work at photon energies from 3 keV up to 16 keV. This wide operation range is a cause for challenges to the focusing optics. In particular, a long propagation distance of about 900 m between x-ray source and sample leads to a large lateral photon beam size at the optics. The beam divergence is the most important …
One of the frontiers of modern electron scattering instrumentation is improving temporal resolution in order to enable the observation of dynamical phenomena at their fundamental time-scales. We analyze how a radiofrequency cavity can be used as an electron longitudinal lens in order to produce a highly magnified temporal replica of an ultrafast process, and, in combination with a deflecting cavity, enable streaked electron images of optical-frequency phenomena. We present start-to-end simulations of an MeV electron beamline for two variations of this idea (a `magnifying-glass' and a `point-pr…
We propose a use of the self-seeding scheme with single crystal monochromator to produce high power, fully-coherent pulses for applications at a dedicated bio-imaging beamline at the European X-ray FEL in the photon energy range between 3.5 keV and 5 keV. We exploit the C(111) Bragg reflection (pi-polarization) in diamond crystals with a thickness of 0.1 mm, and we show that, by tapering the 40 cells of the SASE3 type undulator the FEL power can reach up to 2 TW in the entire photon energy range. The present design assumes the use of a nominal electron bunch with charge 0.1 nC at nominal elect…
We demonstrate a non-invasive time-sorting method for ultrafast electron diffraction (UED) experiments with radio-frequency (rf) compressed electron beams. We show that electron beam energy and arrival time at the sample after rf compression are strongly correlated such that the arrival time jitter may be corrected through measurement of the beam energy. The method requires minimal change to the infrastructure of most of the UED machines and is applicable to both keV and MeV UED. In our experiment with ~3 MeV beam, the timing jitter after rf compression is corrected with 35 fs root-mean-square…
Single biomolecular imaging using XFEL radiation is an emerging method for protein structure determination using the "diffraction before destruction" method at near atomic resolution. Crucial parameters for such bio-imaging experiments are photon energy range, peak power, pulse duration, and transverse coherence. The largest diffraction signals are achieved at the longest wavelength that supports a given resolution, which should be better than 0.3 nm. We propose a configuration which combines self-seeding and undulator tapering techniques with the emittance-spoiler method in order to increase …
We propose a simple laser-driven electron acceleration scheme based on tightly focused radially polarized laser pulses for the production of femtosecond electron bunches with energies in the few-hundreds-of-keV range. In this method, the electrons are accelerated forward in the focal volume by the longitudinal electric field component of the laser pulse. Three-dimensional test-particle and particle-in-cell simulations reveal the feasibility of generating well-collimated electron bunches with an energy spread of 5% and a temporal duration of the order of 1 fs. These results offer a route toward…
We present the results of multi-objective genetic algorithm optimizations of a potential single shot ultra fast electron diffraction beamline utilizing a 100 MV/m 1.6 cell normal conducting rf (NCRF) gun, as well as a 9 cell 2pi/3 bunching cavity placed between two solenoids. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed…
We performed an analysis of coherence properties of the 4-th generation high-energy storage rings with emittance values of 10 pmrad. It is presently expected that a storage ring with these low emittance values will reach diffraction limit at hard X-rays. Simulations of coherence properties were performed with the XRT software and analytical approach for different photon energies from 500 eV to 50 keV. It was demonstrated that a minimum photon emittance (diffraction limit) reached at such storage rings is λ/2π. Using mode decomposition we showed that at the parameters of the storage ring consid…
In an effort to increase spatial and temporal resolution of ultrafast electron diffraction and microscopy, ultra-high brightness photocathodes are actively sought to improve electron beam quality. Beam dynamics codes often approximate the Coulomb interaction with mean-field space charge, which is a good approximation in traditional beams. However, point-to-point Coulomb effects, such as disorder induced heating and the Boersch effect, can not be neglected in cold, dense beams produced by such photocathodes. In this paper, we introduce two new numerical methods to calculate the important effect…
We present the results of multi-objective genetic algorithm optimizations of a potential single shot ultra fast electron diffraction beamline utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at sample location have been performed for three different sample radii: 50, 100, 200 m…
We present two compact ultrafast electron injector designs with integrated focusing that provide high peak brightness of up to $1.9*10^{12} A/m^2Sr^2$ with 10s of electrons per laser pulse using silicon carbide electrodes and silicon nanotip emitters. We demonstrate a few centimeter scale 96 keV immersion lens electron source and a 57 keV immersion lens electron source with a 19 kV/mm average acceleration gradient, nearly double the typical 10 kV/mm used in DC electron sources. The brightness of the electron sources is measured alongside start-to-end simulations including space charge effects.…
A new generation of storage ring-based light source, called diffraction-limited storage ring (DLSR), with emittance approaching the diffraction limit for multi-keV photons by means of multi-bend achromat lattice, has attracted worldwide and extensive studies. Among various DLSR proposals, the hybrid multi-bend achromat concept developed at ESRF predicts an effective way of minimizing the emittance and meanwhile keeping the required sextupole strengths to an achievable level. For the High Energy Photon Source planned to be built in Beijing, an ESRF-type lattice design consisting of 48 hybrid se…
We present the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on a DC photoelectron gun and an SRF linac with multiple independently controlled accelerating and bunching cavities. The design is based on the existing Cornell photoinjector, which can readily be applied to the presented findings. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explore the smallest bunch lengths, emittance, and probe spot sizes achievable. We present results for both stroboscopic conditions (with single electrons…
We report the experimental demonstration of femtosecond electron diffraction using high-brightness MeV electron beams. High-quality, single-shot electron diffraction patterns for both polycrystalline aluminum and single-crystal 1T-TaS2 are obtained utilizing a 5 femto-Coulomb (~3x10^4 electrons) pulse of electrons at 2.8 MeV. The high quality of the electron diffraction patterns confirm that electron beam has a normalized emittance of ~50 nm-rad. The corresponding transverse and longitudinal coherence length are ~11 nm and ~2.5 nm, respectively. The timing jitter between the pump laser and pro…
We use numerical modeling to study the features of parametric (quasi-Cherenkov) cooperative radiation arising when an electron bunch passes through a crystal (natural or artificial) under the conditions of dynamical diffraction of electromagnetic waves in the presence of shot noise. It is shown that in both Laue and Bragg diffraction cases, parametric radiation consists of two strong pulses: one emitted at small angles with respect to the particle velocity direction and the other emitted at large angles to it. Under Bragg diffraction conditions, the intensity of parametric radiation emitted at…
Development of x-ray phase contrast imaging applications with a laboratory scale source have been limited by the long exposure time needed to obtain one image. We demonstrate, using the Betatron x-ray radiation produced when electrons are accelerated and wiggled in the laser-wakefield cavity, that a high quality phase contrast image of a complex object (here, a bee), located in air, can be obtained with a single laser shot. The Betatron x-ray source used in this proof of principle experiment has a source diameter of 1.7 microns and produces a synchrotron spectrum with critical energy E_c=12.3 …
Ultrashort electron beams with narrow energy spread, high charge, and low jitter are essential for resolving phase transitions in metals, semiconductors, and molecular crystals. These semirelativistic beams, produced by phototriggered electron guns, are also injected into accelerators for x-ray light sources. The achievable resolution of these time-resolved electron diffraction or x-ray experiments has been hindered by surface field and timing jitter limitations in conventional RF guns, which thus far are <200 MV/m and >96 fs, respectively. A gun driven by optically-generated single-cycle THz …
In ultrafast electron diffraction (UED) experiments, accurate retrieval of time-resolved structural parameters, such as atomic coordinates and thermal displacement parameters, requires an accurate scattering model. Unfortunately, kinematical models are often inaccurate even for relativistic electron probes, especially for dense, oriented single crystals where strong channeling and multiple scattering effects are present. This article introduces and demonstrates dynamical scattering models tailored for quantitative analysis of UED experiments performed on single-crystal films. As a case study, …