基于相干分析的时延估计

Estimation of time delay by coherence analysis

R. B. Govindan, J. Raethjen, F. Kopper, J. C. Claussen, G. Deuschl

摘要:

使用相干分析(这是一种广泛使用的方法来研究在频域中的相关性,两个同时测量的信号之间),我们估计两个信号之间的时间延迟。该方法适用于传统方法不能可靠应用的窄带相干信号的时延估计。我们通过分析耦合Rössler吸引子与已知的延迟,该方法产生令人满意的结果。然后,我们将此方法应用于人类病理性震颤。同时测量的脑电图(EEG)和肌电图(EMG)的数据与原发性手震颤的主体的痕迹之间的延迟计算。我们发现在脑(EEG)的震颤相关部分(皮层)和颤抖的手(EMG)之间存在11-27毫秒($ms$)的延迟,这与实验观察到的皮层-肌肉传导时间的延迟值15 $ms$一致。通过替代分析,我们计算的误差酒吧的估计延迟。

英文摘要:

Using coherence analysis (which is an extensively used method to study the correlations in frequency domain, between two simultaneously measured signals) we estimate the time delay between two signals. This method is suitable for time delay estimation of narrow band coherence signals for which the conventional methods cannot be reliably applied. We show by analysing coupled Rössler attractors with a known delay, that the method yields satisfactory results. Then, we apply this method to human pathologic tremor. The delay between simultaneously measured traces of Electroencephalogram (EEG) and Electromyogram (EMG) data of subjects with essential hand tremor is calculated. We find that there is a delay of 11-27 milli-seconds ($ms$) between the tremor correlated parts (cortex) of the brain (EEG) and the trembling hand (EMG) which is in agreement with the experimentally observed delay value of 15 $ms$ for the cortico-muscular conduction time. By surrogate analysis we calculate error-bars of the estimated delay.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑