arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv physics/0303067physics.data-an
收藏

厂外停电事故的幂律特性

The power law character of off-site power failures

A. John Arul, C. Senthil Kumar, S. Marimuthu, Om Pal Singh

摘要:

研究了三个核电厂厂址的厂外交流电源故障恢复时间的行为。它示出,幂律是适当的表示故障频率持续时间的关联函数的非现场电源故障事件,基于简单的假设组件故障和修复率。同时发现,停电持续时间的年最大值遵循Frechet分布,这是一个II型渐近分布,加强了我们的假设的父分布的幂律。得到的极值分布用于外推超出观测范围的失效持续时间。

英文摘要:

A study on the behavior of off-site AC power failure recovery times at three nuclear plant sites is presented. It is shown, that power law is appropriate for the representation of failure frequency-duration correlation function of off-site power failure events, based on simple assumptions about component failure and repair rates. It is also found that the annual maxima of power failure duration follow Frechet distribution, which is a type II asymptotic distribution, strengthening our assumption of power law for the parent distribution. The extreme value distributions obtained are used to extrapolate for failure durations beyond the observed range.