arXivDaily arXiv每日学术速递 周一至周五更新
arXiv physics/0209050physics.ins-det
收藏

多孔介质探测器的新研究

New investigations of the porous dielectric detectors

M. P. Lorikyan

摘要:

给出了多孔碘化铯填充的多丝多孔介质探测器和微带多孔介质探测器的研究结果。探测器暴露于能量为5.46 MeV的$α$粒子和能量为5.9 keV的X射线,并在恒定的外加电压下工作。研究发现,热淀积CsI多孔层后,探测器的性能不稳定,空间分辨率差。然而,随着时间的推移,性能变得稳定,并获得高的空间分辨率。

英文摘要:

The results of the study of the multiwire porous dielectric detector and microstrip porous dielectric detector filled with porous CsI are presented. Detectors were exposed to $α$-particles with energy of 5.46 MeV and X-rays with energy of 5.9 keV and operated with a constant applied voltage. It is found that right after thermal deposition of the porous CsI layer the detector's performance is unstable, it has poor spatial resolution. However in a course of time the performance becomes stable and it acquires high spatial resolution.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑