用于宇称破坏实验的高功率氢靶
A High Power Hydrogen Target for Parity Violation Experiments
摘要:
氢和氘的宇称违反电子散射测量,如贝茨和CEBAF实验室正在进行的测量,需要超过$10^{38}$ cm $^{-2}$ s $^{-1}$的亮度,导致大的束功率沉积到低温液体中。这样的目标必须能够吸收500瓦或更多,而目标密度的变化最小。为在贝茨进行的SAMPLE实验研制了一个40厘米长的液氢靶,它能吸收500瓦的束流功率而不沸腾。在最近用40~ $μ$ A的入射光束进行的测试中,在灵敏度水平优于1%时,没有观察到靶中密度起伏的证据。将介绍目标设计和操作经验的摘要。
英文摘要:
Parity-violating electron scattering measurements on hydrogen and deuterium, such as those underway at the Bates and CEBAF laboratories, require luminosities exceeding $10^{38}$cm$^{-2}$s$^{-1}$, resulting in large beam power deposition into cryogenic liquid. Such targets must be able to absorb 500 watts or more with minimal change in target density. A 40~cm long liquid hydrogen target, designed to absorb 500~watts of beam power without boiling, has been developed for the SAMPLE experiment at Bates. In recent tests with 40~$μ$A of incident beam, no evidence was seen for density fluctuations in the target, at a sensitivity level of better than 1\%. A summary of the target design and operational experience will be presented.