聚合准确率掩盖了医学视觉语言模型中特定诊断的失败
Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models
AI总结:
该研究发现医学VLMs的聚合准确率掩盖特定诊断失败,5个模型中2个对气胸完全漏检,内部有表征但输出被抑制,需报告逐检查项指标评估模型。
摘要:
医学视觉语言模型(VLMs)主要通过跨检查项的平均准确率进行比较,这种总结可能会掩盖单个诊断的完全失败。我们在6048个按性别、年龄、检查项和标签平衡的ChestX-ray14问题上审计了5个开源医学VLMs(MedGemma-4B、Lingshu-7B、HuatuoGPT-Vision-7B、Qwen2.5-VL-7B和MedVLM-R1)。在432张气胸阳性X光片上,HuatuoGPT-Vision和Qwen2.5-VL检测到0例,而MedGemma和Lingshu分别检测到38%和67%的相同图像。这两个失败的模型对所有864个气胸案例都回答“否”(平衡准确率为0.500,即随机水平),但会生成流畅且符合解剖学特征的解释,描述肺塌陷的征象后又予以否认,未出现犹豫或弃权(不执行)。这种失败并非提示工程、图像分辨率、标签模糊或模型规模导致的假象,它在四种提示格式、原生分辨率和单标签案例中均存在。模型内对照显示,相同的强制提示使HuatuoGPT对结节的召回率为79%,但对气胸仅为6%;在十倍规模增长后仍存在(Qwen2.5-VL-72B检测到4%),并在独立数据集SIIM-ACR(含放射科医生绘制的掩码)上复现,其中失败模型在432例确诊气胸中检测到0例,包括144个最大病灶中的0个。读取模型的逻辑值和内部状态可知,这并非“看不见”:两个失败模型高度自信但表现仅达随机水平,线性探测可从其隐藏表示中恢复气胸信息(即使召回率为0),说明该征象在内部有表征但在输出端被抑制。因此,聚合准确率无法证明医学VLM能“看到”某一检查项,因为遗漏某一检查项的模型仍能对其做出令人信服的描述,需报告平衡案例上的逐检查项召回率和特异性来区分差异。
英文摘要:
Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。