复杂解剖结构中瞬发伽马时间成像的实验评估

Experimental Assessment of Prompt Gamma Time Imaging in Complex Anatomy

Univ. Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3(格勒诺布尔阿尔卑斯大学);Aix-Marseille Univ, CNRS/IN2P3, CPPM(艾克斯-马赛大学);Department of Biomedicine and Prevention, University of Rome Tor Vergata(罗马托尔维加塔大学生物医学与预防系);Centre Antoine Lacassagne(安托万·拉卡萨涅中心)
Pavel Kavrigin, Alicia Garnier, Adélie André, Chaima Abid, Yannick Boursier, Mathieu Dupont, Giuseppe Fanciulli, Laurent Gallin Martel, Marie-Laure Gallin Marte… 展开作者

Pavel Kavrigin, Alicia Garnier, Adélie André, Chaima Abid, Yannick Boursier, Mathieu Dupont, Giuseppe Fanciulli, Laurent Gallin Martel, Marie-Laure Gallin Martel, Christophe Hoarau, Christian Morel, Jean-François Muraz, Maxime Pinson, Dimitrios Psarras, Nicola Toschi, Daniel Maneval, Sara Marcatili

AI总结:

本研究提出PGTI迭代重建方法,经TIARA探测器实验验证,可在复杂解剖结构中实现质子射程的精准估计,拓展了PG成像在质子治疗体内验证的应用。

摘要:

瞬发伽马(PG)成像是质子治疗中用于体内验证的有前景方法,但现有方法主要局限于重建PG发射分布,仅能提供质子传输的间接信息。本研究引入瞬发伽马时间成像(PGTI),这是一种基于PG计时(PGT)技术的迭代重建方法,可从多个探测器模块获取的飞行时间(TOF)测量数据中联合估计PG发射分布和质子速度分布。与PG分布不同,质子速度与阻止本领直接相关,因此可获取束流穿过的组织组成以及所递送剂量的一阶估计。该方法使用本合作团队此前开发的8模块TIARA原型探测器获取的实验数据进行验证。采用拟人化RANDO头部模体,以100 MeV质子在两种代表治疗计划与递送的解剖构型下进行照射,首次在真实条件下展示了PGTI的应用。在该示例中,重建的材料序列与参考CT一致;尽管有10个分箱出现材料分类错误,重建的质子射程与预期值仅相差约1 mm。这些结果验证了所提出的PGTI框架以及TIARA探测器系统在类临床环境中的应用,将PG成像的应用范围扩展至传统射程验证之外。

英文摘要:

Prompt-gamma (PG) imaging is a promising approach for in vivo verification in proton therapy, but existing methods are primarily limited to reconstructing the PG emission profile, which provides only indirect information on proton transport. In this work, we introduce Prompt-Gamma Time Imaging (PGTI), an iterative reconstruction method based on the PG Timing (PGT) technique that jointly estimates the PG emission distribution and the proton velocity profile from Time-Of-Flight (TOF) measurements acquired with multiple detector modules. Unlike the PG distribution, the proton velocity is directly related to the stopping power and therefore provides access to both the tissue composition traversed by the beam and a first-order estimation of the delivered dose. The method was validated using experimental data acquired with the eight-module TIARA prototype previously developed by our collaboration. The anthropomorphic RANDO head phantom was irradiated with 100 MeV protons in two anatomical configurations representative of treatment planning and delivery, providing the first demonstration of PGTI under realistic conditions. In this example, the reconstructed material sequence agreed with the reference CT; despite ten bins presenting a misclassified material, the reconstructed proton range only differed from the expected value by approximately 1 mm. These results validate both the proposed PGTI framework and the use of the TIARA detector system in a pseudo-clinical environment, extending PG imaging beyond conventional range verification.