基于不确定性引导框架的微滴发生器代理模型增强与逆向设计
Microdroplet Generator Surrogate Enhancement and Inverse Design Through an Uncertainty-Guided Framework
AI总结:
本研究提出不确定性引导框架,结合自适应代理模型增强与粒子群优化,提升微滴发生器设计的液滴预测精度,降低计算成本,可靠识别符合目标尺寸的物理可实现配置。
摘要:
微流控液滴生成对诸多应用至关重要,但由于复杂的多相流动力学,高维参数空间中的高效器件设计在计算上仍难以实现。本研究提出一种统一方法,将自适应代理模型增强与仿真驱动的逆向设计相结合。高保真的流体体积法(Volume-of-Fluid)仿真提供真实数据,而神经网络集成模型用于预测流型和液滴直径。基于集成的不确定性量化通过流型分类的共识水平和直径预测的变异系数识别认知不确定性,结果表明不确定性集中在流型转变边界附近,该区域的物理特性对参数扰动高度敏感。一种物理信息增强策略针对这些关键区域,通过部署额外的目标仿真并重新训练构成集成的代理模型,解决类别不平衡问题。因此,本研究提出一种集成粒子群优化(Particle Swarm Optimization)的框架,用于约束逆向设计,在准确性、预测置信度和物理一致性之间取得平衡。对独立测试数据集的验证表明,增强后的集成模型实现了更高的准确性,液滴直径预测误差在0-3%范围内的比例几乎翻倍,误差高于10%的高误差案例大幅减少。逆向设计流程可靠地识别出符合目标液滴尺寸的物理可实现配置。该方法显著降低了计算成本,同时确保预测可靠,为广泛微流控系统的优化提供了具有潜在适用性的框架。
英文摘要:
Microfluidic droplet generation is critical for many applications, yet efficient device design in high-dimensional parameter spaces remains computationally prohibitive due to complex multiphase flow dynamics. This work presents a unified methodology that couples adaptive surrogate enhancement with simulation-driven inverse design. High-fidelity Volume-of-Fluid simulations provide ground-truth data, while neural network ensembles predict flow regimes and droplet diameters. Ensemble-based uncertainty quantification identifies epistemic uncertainty using consensus levels for regime classification and the coefficient of variation for diameter prediction, revealing that uncertainty concentrates near regime transition boundaries where physics is highly sensitive to parameter perturbations. A physics-informed enrichment strategy targets these critical zones and addresses class imbalances by deploying additional targeted simulations and retraining the surrogates forming the ensembles. A framework that integrates Particle Swarm Optimization for constrained inverse design, balancing accuracy with predictive confidence and physical consistency is therefore proposed. Validation on independent test datasets demonstrates that the enriched ensembles achieve higher accuracy, with the fraction of predictions within the 0-3% error range on droplet diameter nearly doubling, and high-error cases (above 10%) dropping substantially. The inverse design procedure reliably identifies physically realizable configurations meeting target droplet sizes. This approach significantly reduces computational costs while ensuring reliable predictions, offering a framework with potential applicability to the optimization of a broad range of microfluidic systems.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。