arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2611.06452cs.CVcs.AIcs.LG
收藏

固定分辨率迁移学习下的家族内EfficientNet缩放用于光谱域光学相干断层扫描视网膜疾病分类

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

University of Tetova(特托瓦大学)

Shkelqim Sherifi

AI总结:

该研究评估EfficientNet-B0至B7在固定分辨率SD-OCT视网膜疾病分类中的表现,发现更大EfficientNet变体未持续提升性能,B1准确率最高,B7在更大规模下有次要准确率恢复,缩放效果依赖任务与协议。

摘要:

背景/目标:卷积神经网络(CNNs)在光谱域光学相干断层扫描(SD-OCT)的视网膜疾病分类中表现良好,但EfficientNet针对自然图像的缩放层级是否能迁移到固定分辨率的医学图像迁移学习中仍不明确。本研究评估EfficientNet-B0至B7在四类SD-OCT分类中的表现及准确率-效率权衡。方法:在Kermany数据集上,对8个ImageNet预训练变体(实例化骨干网络参数为4.05至64.10M)在224×224分辨率下进行评估,将灰度图像复制为RGB格式,使用模型内置的预处理和增强方法处理,训练流程为冻结骨干网络的头部训练后进行部分微调,指标涵盖分类、判别、效率及视觉分析。结果:测试准确率呈非单调变化,从B0的95.93%到B1的96.95%,B7达到96.73%;B1具有最高准确率和Drusen的F1值(0.8780),B7的Drusen F1值为0.8720且Drusen召回率最高(0.9177);所有变体中Drusen的F1值最低,占类别特定F1平方偏差总和的82.2%,类别排序为正常>CNV>DME>Drusen;SD-OCT的准确率排序与已报道的ImageNet层级不同,ImageNet中B7排名第一;准确率-参数比从每百万总参数19.82个百分点降至1.48个百分点;最终训练-测试差距与测试准确率呈弱且无统计学意义的关联(r=0.26,p=0.53)。结论:更大的EfficientNet变体并未持续提升SD-OCT分类性能,B1实现最高准确率和Drusen F1,而B7在更大模型规模和CPU延迟下表现出次要的准确率恢复,表明缩放效果依赖于任务和协议;由于跨分区重复数据未经过独立审核,结果基于提供的划分具有条件性。

英文摘要:

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑