肌电(EMG)标记化以仅需一小部分比特率即可保留运动信息
EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate
AI总结:
该研究提出两种EMG因果标记器,在满足1 mm非劣效性标准的前提下,将EMG有效载荷减少36-41倍,且在emg2pose基准测试中误差差异极小,可作为可穿戴传感与运动解码的紧凑接口。
摘要:
无线肌电(EMG)接口必须在电极覆盖范围与传输带宽之间取得平衡。本文表明,紧凑的EMG标记可大幅减少有效载荷,同时保留用于三维手部姿态解码的信息。我们评估了两种无需姿态标签即可拟合的因果标记器:一种是预训练用于重建EMG频谱的编码器,另一种是基于SPAR(相邻电极的工程化频谱-空间表示)的标记器。在9名参与者的320通道EMG个性化会话内实验中,我们使用匹配的解码器架构和训练程序比较了标记化特征与连续特征。在所有解码器上取平均,标记化使SPAR的平均误差变化为+0.01 mm(95%置信区间:-0.12至0.14),使学习到的表示的平均误差变化为+0.45 mm(0.10至0.82)。两种误差增加均满足1 mm的非劣效性标准。与原始EMG相比,存储的标记阵列将有效载荷减少了41倍;与连续SPAR特征相比,减少了36倍。在公共emg2pose基准测试集的采样窗口上,学习到的标记与连续特征之间的平均误差绝对差异在176名参与者及训练期间未见过的20名参与者子集中均低于0.05 mm。电极覆盖范围、校准和未见过的记录对SPAR解码的影响大于量化的影响。在计算基准测试中,优化后的SPAR在Cortex-M55微控制器上可在20 ms内为63个通道生成标记。这些发现支持标记化作为可穿戴传感与运动解码之间的紧凑接口,允许更新解码器,同时保持可穿戴编码器和传输表示固定不变。
英文摘要:
Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。