arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.30035cs.CV
收藏

看似合理但无法植入:颅骨缺损重建形状补全基础模型的可信性审计

Plausible but Unimplantable: A Trustworthiness Audit of Shape Completion Foundation Models for Cranial Defect Reconstruction

AGH University of Krakow(克拉科夫AGH科技大学);Sano Centre for Computational Medicine(萨诺计算医学中心)

Marek Wodzinski, Kamil Kwarciak, Daria Hemmerling, Mateusz Daniol

AI总结:

本研究审计了3个形状补全模型(含2个基础模型),发现其在239例颅骨缺损上均无法生成可植入的修复体,无法满足临床需求,需进一步研发可信的形状补全基础模型。

摘要:

失去部分颅盖骨的患者需要一个与缺损完全贴合的植入物,目前这类植入物仍由专家在CAD中手动绘制,导致每个病例的处理过程缓慢且成本高昂。该任务可视为形状补全问题,因此预训练的补全模型以及如今首个形状补全基础模型,似乎是消除手动步骤的一种途径。我们审计了三个公开可用的预训练形状补全模型,其中两个为基础模型,将其零样本应用于239例颅骨缺损(部分来自公共颅骨数据集的人工雕刻缺损,部分为真实颅骨切除术后病例)。将每个输出与仅返回患者自身剩余骨组织的情况进行比较,测试预测的植入物材料是否可在不与剩余骨组织相交的情况下放置。在210例人工雕刻缺损中,三个模型均未优于不进行任何操作的效果;在29例真实病例中,仅一个模型的效果超出随机水平。然而,无论何种模型、何种配置,没有一个输出是可植入的:没有一个模型能同时满足避开患者剩余骨组织且放置的材料多于不进行任何操作的情况,而针对该任务训练并在这些病例上选定的特定体积模型,除1例外均为可植入的。最接近颅骨外观的输出与其他输出一样无法放置,且在这些点密度下,植入物厚度完全无法从输出点中读取,这是输出表示的属性而非任何单个模型的问题。基于此证据,我们可获取的形状补全基础模型不可信,按现有发布版本无法在临床实践中使用,仍需开展大量研究以开发可信的形状补全基础模型。

英文摘要:

A patient who has lost part of the skull vault needs an implant that fits the defect exactly, and such implants are still drawn by hand in CAD by specialists, which makes each case slow and expensive. The task can be considered as a shape completion problem, so pretrained completion models, and now the first shape completion foundation models, look like a way to remove that manual step. We audited three publicly released pretrained shape completion models, two of them foundation models, applied zero-shot to 239 cranial defects, some carved from public skull datasets and some real post-craniectomy cases. Each output was compared with simply returning the patient's own remaining bone, and tested for whether the predicted material could be placed without intersecting the bone that is still there. On the 210 carved defects none of the three improved on doing nothing, and on the 29 real cases only one did so beyond chance. Yet not one output, from any model in any configuration, was implantable: none managed both to stay clear of the bone the patient still has and to place more material than doing nothing, where a task-specific volumetric model, trained for this task and selected on these cases, was implantable on all but one. The output that most convincingly resembles a skull is no more placeable than the rest, and at these point densities implant thickness cannot be read off the emitted points at all, which is a property of the output representation rather than of any one model. On this evidence the shape completion foundation models we could obtain cannot be trusted and, used as released, are not usable in clinical practice. Substantial research towards trustworthy foundation models for shape completion is still needed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑