arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.24044eess.IVcs.CVq-bio.TO
收藏

GliomaINK:用于胶质瘤患者3D MRI序列合成的肿瘤与解剖条件流匹配框架

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

Columbia University Irving Medical Center(哥伦比亚大学欧文医学中心);Atal Bihari Vajpayee Institute of Medical Sciences(阿塔尔·比哈里·瓦杰帕伊医学科学研究所);Stony Brook University(石溪大学)

Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh

AI总结:

本研究提出GliomaINK框架,采用3D SwinUNETR与拓扑保持损失实现跨序列胶质瘤MRI合成,在PSNR、肿瘤分割Dice及IDH1预测AUROC等指标上优于对比方法,可保留临床信息并改善下游任务。

摘要:

背景:不完整的多参数MRI检查限制了胶质瘤的表征及下游AI工具的应用。生成模型可合成缺失的MRI序列,但难以保留解剖结构和临床相关的肿瘤特征。我们提出GliomaINK,一种用于跨序列3D脑MRI合成的解剖引导条件流匹配框架。方法:3D SwinUNETR预测条件速度场,同时辅助拓扑保持损失鼓励结构一致性。该模型在BraTS-AG数据集的1083例患者上训练,并在内部临床队列中独立测试。下游任务包括图像质量、肿瘤分割、IDH1突变状态预测及总生存期预测。两名放射科医生独立评估合成图像的解剖保真度、病理表征及整体图像质量。结果:GliomaINK在两个评估队列的所有6种MRI转换方向中均表现出最高的PSNR。在BraTS-AG测试集中,T2W到T1C合成的PSNR达到25.64±0.55 dB,而Pix2Pix为13.78±0.32 dB,SPADE为18.90±0.53 dB。对于下游肿瘤分割,该方法在肿瘤亚区域表现出强性能,水肿的Dice分数达到0.928±0.014,强化肿瘤为0.885±0.040。对于IDH1突变状态预测,GliomaINK在6种序列配置中的4种达到最高AUROC分数,为0.827±0.088。结论:解剖引导的条件流匹配可实现高保真的跨序列胶质瘤MRI合成,显示出在合成MRI中保留临床相关信息并改善下游任务的潜力。

英文摘要:

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑