arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2610.21041hep-phastro-ph.COastro-ph.GAhep-ex
收藏

利用重元素实验检验LZ事件的非弹性暗物质解释

Testing the inelastic dark matter interpretation of the LZ event with heavy-element experiments

Stanford University(斯坦福大学);University of Delaware(特拉华大学);Bartol Research Institute(巴托尔研究所);University of Washington(华盛顿大学)

Peter W. Graham, Juan P. Luengas, Harikrishnan Ramani, Samuel S. Y. Wong

AI总结:

本文针对LZ实验观测的248 keV事件的非弹性暗物质解释,利用受LMC影响启发的速度分布,结合重元素古探测器、配备重元素补充的大型中微子探测器等,检验暗物质模型并破解参数简并。

摘要:

我们考虑LZ实验近期观测到的248 keV事件的非弹性暗物质解释,并确定可对其进行检验的不同实验。 underlying模型的细节以及互补实验对其的检验能力,很大程度上取决于暗物质分布的高速尾部。我们考虑了数个受大麦哲伦云(LMC)影响启发的示例速度分布,以阐明这种依赖性的效应。例如,我们说明何种类型的高速尾部能使热希格斯ino在太阳中微子的严格约束下仍可行:相较于模拟结果减少尾部通量可改善希格斯ino的拟合,而将尾部延伸至当前模拟分辨率以下的更高速度则可规避太阳中微子约束。这推动开展更高分辨率的更详细模拟以更好地理解该尾部。即便氙实验证实了该信号事件,仍需互补实验以检验 underlying模型是否为非弹性暗物质,并破解暗物质参数(如质量和质量分裂)测量中的简并性。重元素古探测器可覆盖与LZ事件相关的大部分参数空间,其使用不同元素的特性可确定暗物质质量和分裂,且其对暗物质分布历史的独特敏感性可检验信号的LMC起源。配备重元素补充的大型中微子探测器的发光探测可直接检验信号的非弹性质并测量质量分裂,同时其对辐射衰变率的敏感性可为希格斯ino解释提供有力证据。

英文摘要:

We consider the inelastic dark matter interpretation of the recent 248 keV event observed by LZ and identify different experiments that could test it. Details of the underlying model and the ability of complementary experiments to test it depend significantly on the high-velocity tail of the dark matter distribution. We consider several example velocity distributions motivated by the impact of the Large Magellanic Cloud (LMC) in order to map out the effects of this dependence. For example, we illustrate the type of high-velocity tail that would make the thermal Higgsino viable despite stringent constraints from solar neutrinos: Reducing the flux of the tail relative to simulation results improves the Higgsino fit, while extending the tail to higher velocities at fluxes below current simulation resolution evades the solar neutrino bound. This motivates more detailed simulations at higher resolution to understand the tail better. Even if xenon experiments confirm the signal event, complementary experiments are still required to test whether the underlying model is inelastic dark matter and to break degeneracies in the measurement of dark matter parameters such as mass and mass splitting. Heavy-element paleodetectors could cover most of the parameter space relevant to the LZ event. Their use of different elements could determine the dark matter mass and splitting, while their unique sensitivity to the history of the dark matter distribution could test the signal's LMC origin. Luminous detection in large neutrino detectors with heavy-element supplements could directly test the inelastic nature of the signal and measure the mass splitting, while its sensitivity to the radiative decay rate could provide strong evidence for the Higgsino interpretation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑