arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2610.19938gr-qcastro-ph.IM
收藏

扭杆萨格纳克速度计中的量子噪声与扭矩关联

Quantum noise and torque correlations in a torsion-bar Sagnac speed meter

National Central University(国立中央大学);Center for High Energy and High Field (CHiP), National Central University(国立中央大学高能高场中心);Institute of Physics, Academia Sinica(中央研究院物理学研究所);Institute of Particle and Nuclear Studies, High Energy Acceleration Research Organization (KEK)(高能加速器研究机构粒子与核研究部);National Institute of Physics, University of the Philippines - Diliman(菲律宾大学迪利曼分校国立物理研究所);INFN Sezione di Ferrara(费拉拉意大利国家核物理研究所分部);National Astronomical Research Institute of Thailand(泰国国家天文研究所)

Yuki Inoue, Mario Onglao, Daiki Tanabe, Masashi Hazumi, Vivek Kumar, Apimook Watcharangkool

AI总结:

该研究针对用于低频引力波探测的CHRONOS扭杆萨格纳克速度计,发现后方真空场是其低频量子噪声的主要来源,为镜和读出设计提供了定量要求。

摘要:

对于用于低频引力波探测的扭杆萨格纳克速度计,即使其光学布局抑制了辐射压力反作用,透过弱透射镜进入的量子涨落仍可能对其性能造成限制。我们在采用量子非破坏性速度计的低温亚赫兹交叉扭杆探测器(CHRONOS)中发现,尽管每根扭杆两端的扭矩相互抵消,但从端测试质量和中间测试质量后方进入的真空场仍会主导低频量子噪声。在镜功率透射率仅为$10^{-7}$的参考配置下,这些场在0.1Hz处贡献了总量子噪声功率谱密度的89.7%,若忽略它们,振幅谱密度将被低估3.11倍。我们的输入输出模型将连续光学相互作用产生的关联与每根扭杆上的力及测量信号关联起来,该关联解释了为何强扭矩抵消本身并不能确保探测器灵敏度相应提升。在固定反射率下,将镜透射率替换为吸收,对所研究的两个工作点而言,过量量子噪声基本保持不变。当回收失谐和零差角变化时,预测的信号响应与量子噪声与独立的FINESSE 3计算结果一致。这些结果确立了后方真空场是该扭杆速度计的限制噪声源,并为其镜和读出设计提供了定量要求。

英文摘要:

Quantum fluctuations entering through weakly transmitting mirrors can limit a torsion-bar Sagnac speed meter for low-frequency gravitational-wave detection, even when its optical layout suppresses radiation-pressure back action. We show that, in the Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS), vacuum fields entering from behind the end and middle test masses can dominate the low-frequency quantum noise despite cancellation of the torques on opposite ends of each bar. For a reference configuration with mirror power transmissions of only $10^{-7}$, these fields contribute $89.7\%$ of the total quantum-noise power spectral density at 0.1 Hz. Omitting them would underestimate the amplitude spectral density by a factor of 3.11. Our input-output model connects the correlations produced by successive optical interactions to the forces on each bar and the measured signal. This connection shows why strong torque cancellation does not, by itself, ensure a corresponding improvement in detector sensitivity. Replacing mirror transmission with absorption at fixed reflectivity leaves the excess quantum noise essentially unchanged for the two operating points studied. The predicted signal response and quantum noise agree with independent FINESSE 3 calculations as recycling detuning and homodyne angle are varied. These results establish rear vacuum fields as a limiting noise source in this torsion-bar speed meter and provide quantitative requirements for its mirror and readout design.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑