仿脑体模与离体脑组织中的短程微波探针间耦合

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

Bradley Department of Electrical and Computer Engineering, Virginia Tech(弗吉尼亚理工学院布莱德利电气与计算机工程系)

Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling

AI总结:

本文通过仿脑体模与离体山羊脑实验,表征了带12毫米金属丝的印刷锥形槽耦合探针的短程微波耦合特性,验证了其在5.78-6.86 GHz频段的响应一致性,为相关生物微波测量提供了实验依据。

摘要:

本文通过脑模拟琼脂-明胶-生理盐水体模和离体脑组织,对带有部分插入的12毫米金属丝元件的印刷锥形槽耦合探针的短程微波耦合特性进行了表征。在5.78至6.86 GHz的实测-10 dB带宽范围内,自由空间S₁₁响应的仿真与实测结果吻合,该带宽为1.08 GHz,分数带宽约为17.1%。在受控双探针实验中,在保持探针布置和测量条件不变的情况下,先后引入和移除体模,在相同的保留布置下重复该对比,各次重复均观察到大致相同的S₂₁差分行为。在6.3 GHz附近,存在体模时实测S₂₁约为-25 dB,在空气中约为-40 dB,对应差值约为16 dB。离体山羊脑测量重复五次以上,表现出可重复的行为。在5.78至6.86 GHz范围内,离体山羊脑的S₂₁响应与体模的响应密切吻合,由图得出的最大工作带宽差值约为1.5 dB。观察到的|S₂₁|增大被解释为完整探针-介质-探针系统的特性,包括负载、互耦合、界面、几何结构、传播和材料损耗。该测量无法唯一确定组织内在机制。

英文摘要:

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑