arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.15076cs.LGphysics.plasm-ph
收藏

面向等离子体重构的多模态基础模型

Toward a Multimodal Foundation Model for Plasma State Reconstruction

School of Physics(物理学院);Georgia Institute of Technology(佐治亚理工学院);Boston University(波士顿大学);Princeton Plasma Physics Laboratory(普林斯顿等离子体物理实验室);Princeton University(普林斯顿大学);Los Alamos National Laboratory(洛斯阿拉莫斯国家实验室);Carnegie Mellon University(卡内基梅隆大学)

Bin Xia, Chuanfei Dong, Boting Li, Yilan Qin, Zikang Xie, Sung Hyun Son, Adam J. Stanier, Jongsoo Yoo, Hantao Ji, Ahmed Diallo, Han Ding, John Wise

AI总结:

本研究提出一种多模态基础模型,基于250个VPIC模拟训练550万参数残差3D U-Net,可实现等离子体重构的跨模态补全,0.1%磁场可见性即可大幅降低密度重构误差。

摘要:

等离子体实验通过稀疏、异构且不完整的诊断观测耦合物理状态。受实验室重联实验装置(Facility for Laboratory Reconnection Experiments, FLARE)的启发,我们提出了一种用于磁重联期间等离子体重构的多模态基础模型的概念验证。我们使用250个固定参考电子beta(β_e0=0.2)的合成VPIC模拟,其中225个用于训练,25个不相交的用于验证,训练了一个550万参数的残差3D U-Net,以从不完整观测中重构三个磁场分量和电子密度。该模型结合了仅空间池化(保留全部24个时间帧)、全局时空自注意力和旋转位置编码。通过随机、网格、块和时间模式独立屏蔽磁场和密度模态,可实现稀疏感知、跨模态补全、密度超分辨率和时间补全,且仅需一组权重,无需针对特定任务重新训练。当密度完全隐藏时,仅0.1%的磁场空间可见性即可将中位数密度归一化均方根误差(NRMSE)从约0.9降至0.1。相反,当磁场数据缺失或极度稀疏时,观测到的密度可改善电流密度重构。在无磁场观测的情况下,约1%的密度可见性可达到磁场完全观测时的密度重构精度,尽管电流结构仍更依赖直接磁场测量。完整的磁场条件输入还可稳定缺失未来密度帧的补全。这些结果证明了该模拟机制内的双向跨模态预测耦合。跨等离子体机制或实验测量的泛化性仍未得到验证。

英文摘要:

Plasma experiments observe coupled physical states through sparse, heterogeneous, and incomplete diagnostics. We present a proof of concept toward a multimodal foundation model for plasma state reconstruction during magnetic reconnection, motivated by the Facility for Laboratory Reconnection Experiments (FLARE). Using 250 synthetic VPIC simulations at fixed reference electron beta $β_{e0}=0.2$, with 225 training runs and 25 disjoint validation runs, we train a 5.5M-parameter residual 3D U-Net to reconstruct three magnetic-field components and electron density from incomplete observations. The model combines spatial-only pooling, which preserves all 24 temporal frames, with global spatiotemporal self-attention and rotary positional encoding. Independently masking magnetic and density modalities across random, grid, block, and temporal patterns enables sparse sensing, cross-modal completion, density super-resolution, and temporal completion with a single set of weights and no task-specific retraining. With density fully hidden, just 0.1% magnetic spatial visibility reduces median density NRMSE from approximately 0.9 to 0.1. Conversely, observed density improves current-density reconstruction when magnetic data are absent or extremely sparse. With no magnetic observations, roughly 1% density visibility approaches the density reconstruction accuracy achieved with fully observed magnetic fields, although current structure remains more dependent on direct magnetic measurements. Full magnetic conditioning also stabilizes completion of missing future density frames. These results demonstrate bidirectional cross-modal predictive coupling within this simulation regime. Generalization across plasma regimes or to experimental measurements remains untested.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑