本研究结合外观、空间上下文与时间约束,通过含71段录像的数据集训练模型,提升了光学套管针穿刺时的腹壁组织识别与起始定位性能,但仍存在组织特异性局限等问题需进一步验证。

摘要:

目的:评估空间上下文与时间建模是否能改善光学套管针穿刺过程中的组织识别,该过程中可能同时可见多层腹壁组织。方法:我们回顾性分析了71段录像,包含1516个标注关键帧和29151个临床医生标注的扇区。每帧被划分为28个极网格扇区,对应9类组织。梯度提升发射分类器使用颜色、相邻扇区及位置特征,完整流程还加入了学习到的时间平滑、空间正则化、解剖学有序隐马尔可夫模型及后验融合。五折交叉验证按录像分组,采用交叉拟合防止录像内数据泄露。主要评估使用临床医生设定的目标;消融实验评估分类、概率质量、空间一致性及腹膜或更深层的起始时间。结果:完整流程的准确率为0.646,宏F1值为0.507,宏AUROC为0.882,而仅用发射分类器时分别为0.600、0.440、0.861;所有五折交叉验证的宏F1值提升了0.066。每扇区每分钟的标签变化从66.2降至19.5,中位起始误差从15.58秒降至2.45秒。组织深度码跨度至少为3的帧占比从53%降至26%,而临床医生标注的对应占比为22%。腹膜前脂肪和肠管的性能仍有限,完整模型仍有44%的过早起始比例。结论:结合外观、空间上下文和时间约束可改善回顾性组织识别与起始定位;组织特异性局限、残留时间误差及对未来观测的依赖,需在临床应用前进行外部验证和因果模型的前瞻性评估。

英文摘要:

Objective. To evaluate whether spatial context and temporal modeling improve tissue recognition during optical trocar entry, where multiple abdominal-wall tissues may be visible simultaneously. Methods. We retrospectively analyzed 71 recordings with 1,516 annotated keyframes and 29,151 clinician-annotated sectors. Each frame was divided into 28 polar-grid sectors assigned to nine tissue classes. Color, neighboring-sector, and positional features were used by a gradient-boosted emission classifier. The full pipeline added learned temporal smoothing, spatial regularization, an anatomically ordered hidden Markov model, and posterior blending. Five-fold cross-validation was grouped by recording, with cross-fitting to prevent within-recording leakage. Primary evaluation used clinician-derived targets; ablations assessed classification, probability quality, spatial consistency, and peritoneum-or-deeper onset timing. Results. The complete pipeline achieved accuracy 0.646, macro-F1 0.507, and macro-AUROC 0.882, versus 0.600, 0.440, and 0.861 for emissions alone. Macro-F1 improved by 0.066 across all five folds. Label changes decreased from 66.2 to 19.5 per sector-minute, and median onset error decreased from 15.58 to 2.45 seconds. Frames with a tissue-depth-code span of at least three decreased from 53% to 26%, versus 22% for clinician annotations. Performance remained limited for preperitoneal fat and bowel, and the full model retained a 44% premature-onset proportion. Conclusions. Combining appearance, spatial context, and temporal constraints improved retrospective tissue recognition and onset localization. Tissue-specific limitations, residual timing errors, and reliance on future observations warrant external validation and prospective evaluation of causal models before clinical use.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑