多模态决策模型能否对乳腺超声图像进行分类?在不同提示和数据集上对CLEF与CLEF-Flash进行基准测试
Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets
AI总结:
本研究在三个乳腺超声数据集上对CLEF与CLEF-Flash在三种提示下的分类性能进行基准测试,发现性能依赖于数据集和提示,CLEF-Flash在临床提示下准确率最高,CLEF在BUSI任务引导提示下宏F1值最高,CLEF-Flash延迟更低。
摘要:
多模态决策模型会返回预定义备选方案的概率,为图像分类提供结构化接口。本研究在来自数据集B、BUSI和BUS-BRA的2818张乳腺超声图像上,对CLEF与CLEF-Flash的推理性能进行基准测试。数据集B和BUS-BRA采用良性-恶性二分类,而BUSI包含正常、良性和恶性三类。模型参数保持不变,且提交的原始图像未经过用户定义的预处理。三种提示分别提供最小标签、明确的分类任务或超声检查标准。我们报告了准确率、宏F1值、平衡准确率、宏精确率、吞吐量和延迟。CLEF-Flash在临床提示下在所有三个数据集上均达到最高准确率:数据集B上为74.85%,BUSI上为66.28%,BUS-BRA上为51.63%。然而在BUSI上,CLEF在任务引导提示下达到最高宏F1值(64.51%)和平衡准确率(68.72%)。在所有匹配的比较中,CLEF-Flash的延迟更低。与最小提示相比,临床提示可提高CLEF-Flash的准确率,但会降低CLEF在所有数据集上的准确率。混淆矩阵显示存在频繁的良性到恶性的错误,尤其是在BUS-BRA上,所有配置的准确率均低于多数类预测器的67.63%。这些发现表明性能依赖于数据集和提示,为将多模态决策模型应用于乳腺超声分析,需进行类别特定评估。
英文摘要:
Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。