HIRFL-CSR外靶实验中T0探测器的基于CNN的位置重建
CNN-based Position Reconstruction for the T0 Detector in the HIRFL-CSR External-target Experiment
AI总结:
本研究提出基于CNN的位置重建方法,使HIRFL-CSR外靶实验的T0探测器兼具事例起始时间探测与高计数率束流斑监测功能,实验验证了其可行性。
摘要:
T0探测器为HIRFL-CSR外靶实验提供事例起始时间,其多通道读出信号还包含入射粒子的二维位置信息。在CEE实验中,专用束流轮廓探测器的计数率仅约1 kHz,远低于最高达1 MHz的束流事例率,因此无法在高计数率数据获取条件下提供实时束流斑监测或事例时间参考。为填补这一空白,本研究提出一种基于CNN的位置重建方法,使T0探测器可同时提供起始时间和束流斑信息。将32个SiPM通道的阈值以上时间与过阈值时间(TOT)值重组为保留几何结构的输入张量;通过逐事例均值相减校正时间特征,通过逐事例截尾均值对TOT特征进行归一化后再进行特征标准化;定制的CNN直接回归入射坐标。训练与验证样本由Geant4模拟和波形数字化构建,采用带有已知位置标签的脉冲激光扫描数据集对方法进行评估。在独立测试集上,均匀分布的平面模拟数据在x、y方向的残差标准差约为1.11 mm和1.04 mm;对于离散激光扫描几何结构,模拟中的分辨率在x、y方向约为2.36 mm和1.34 mm,实验中的分辨率约为2.42 mm和1.41 mm。将训练好的模型应用于2026年1月在兰州近代物理所采集的CEE零场束流数据,重建得到二维束流斑分布。这些结果表明,T0探测器在保留其作为事例起始时间探测器功能的同时,具备作为高计数率束流斑监测器的潜力。
英文摘要:
The T0 detector provides the event start time for the HIRFL-CSR external-target experiment, and its multi-channel readout signals also contain 2D position information of incident particles. In the CEE experiment, the dedicated beam-profile detector has a rate capability of only ~1 kHz, far below the beam event rate of up to 1 MHz, so it cannot provide real-time beam-spot monitoring under high-rate data-taking or an event time reference. To fill this gap, this work studies a CNN-based position reconstruction method that enables the T0 detector to provide both start time and beam-spot information. The over-threshold times and time-over-threshold (TOT) values from 32 SiPM channels are reorganized into a geometry-preserving input tensor. Time features are corrected by event-wise mean-time subtraction, and TOT features are normalized by an event-wise trimmed mean before feature standardization. A customized CNN directly regresses the incident coordinates. Training and validation samples are built with Geant4 simulation and waveform digitization, and the method is evaluated using a pulsed-laser scanning data set with known position labels. On independent test sets, the residual standard deviations for uniformly distributed planar simulation data are about 1.11 and 1.04 mm in x and y. For the discrete laser-scanning geometry, the resolutions are about 2.36 and 1.34 mm in simulation and 2.42 and 1.41 mm in experiment. The trained model is applied to CEE zero-field beam data collected at the Institute of Modern Physics, Lanzhou, in January 2026, and a 2D beam-spot distribution is reconstructed. These results show the T0 detector's potential as a high-rate beam-spot monitor while retaining its role as an event start-time detector.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。