GlucoPRISM:用于跨队列血糖迁移的协议监督预训练
GlucoPRISM: Protocol-Supervised Pretraining for Cross-Cohort Glucose Transfer
AI总结:
本研究提出 GlucoPRISM 协议监督预训练方法,通过分离表征中损害血糖跨队列迁移的设备相关分量,在 12 个跨队列方向上将平均迁移 AUROC 提升至 73.57,在公共任务及外部临床队列中均取得显著性能提升。
摘要:
连续血糖监测(CGM)基础模型将每一天编码为一个向量,该向量混合了个体特征、当日发生事件以及传感器测量结果,因此测量差异会随表征一同迁移至新队列。本文探究预训练是否能将损害迁移的测量分量置于已知坐标,从而在部署时通过固定投影去除该分量,无需目标数据。GlucoPRISM 利用响应契约监督 GlucoFM 主干网络,响应契约规定仅当日或仅传感器变化时,表征各部分应如何改变:64 维 Trait 带应保持不变,48 维 State 带仅随日期变化,16 维 Sensor 带应跟踪设备。基于配对 Dexcom 与 Libre 记录校准的合成传感器视图、不同日期对及血糖摘要目标提供了此类监督,无需临床标签。在 12 个跨队列方向中,从相同冻结编码器中去除 Sensor 带使平均迁移 AUROC 从 68.75 提升至 73.57,而 GlucoFM 的 AUROC 为 69.3。该提升分为两部分:在记录了两种传感器类型的目标队列 CGMacros 中,过滤使 AUROC 提升 11 至 19 个点,且当生成器在一半参与者上重新校准并在另一半上评分时,该效果依然存在;在其余 8 个方向中,过滤无影响,编码器本身比 GlucoFM 提升 3.5 个点。过滤后设备仍可线性解码,说明过滤器去除的是损害迁移的设备相关分量,而非所有测量信息。保留的带在 14 个公共任务-队列单元中的 13 个上提升了窗口 AUROC(经 Holm 校正后 p=0.031),并在包含 9303 名参与者的外部队列的 15 个临床终点中的 14 个上提升了相关性。
英文摘要:
Continuous glucose monitoring (CGM) foundation models encode each day as one vector that mixes who the person is, what happened that day and how the sensor measured it, so measurement differences travel with the representation into new cohorts. We ask whether pretraining can place the measurement component that harms transfer in known coordinates, so that deployment drops them with a fixed projection and no target data. GlucoPRISM supervises a GlucoFM backbone with response contracts, rules for how each part of the representation should change when only the day or only the sensor changes: a 64-dimensional Trait band should change with neither, a 48-dimensional State band only across days, and a 16-dimensional Sensor band should track the device. Synthetic sensor views calibrated on paired Dexcom and Libre recordings, different-day pairs and glucose-summary targets supply this supervision without clinical labels. Across twelve cross-cohort directions, dropping the Sensor band from the same frozen encoder raises mean transfer AUROC from 68.75 to 73.57, against 69.3 for GlucoFM. The gain has two parts. Into CGMacros, the one target cohort recorded with two sensor types, filtering adds 11 to 19 points, and this holds when the generator is recalibrated on half of the participants and scored on the other half. On the other eight directions filtering is neutral and the encoder itself exceeds GlucoFM by 3.5 points. The device remains linearly decodable after filtering, so the filter removes a device-related component that harms transfer rather than all measurement information. The retained bands improve window AUROC on thirteen of fourteen public task--cohort cells (Holm-adjusted p=0.031) and correlation on fourteen of fifteen clinical endpoints in an external cohort of 9,303 participants.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。