arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~

HandAnthro:基于单张图像的手部自动人体测量

HandAnthro: Automated Hand Anthropometry from a Single Image

Fan Zhou, Shuairan Chen, Mengying Zhang, Yulin Wu, Sadegh Jafari, Sixing Yu, Rui Li, Ali Jannesari, Guowen Song

arXiv 2609.37855首次发表:更新:

发表机构

Iowa State University; Microsoft(爱荷华州立大学; 微软)

机构由 AI 辅助整理,请以论文原文为准。

AI 中文总结

HandAnthro从单张手掌照片自动估计44个手部尺寸,结合YOLO姿态模型与几何轮廓细化关键点,在受控实验中达到3.80毫米平均误差,并验证了现场可行性。

AI 中文摘要

手部人体测量为防护手套设计提供支持,但现有的测量方法通常需要训练有素的操作员、专用硬件或手动标记关键点。我们提出了HandAnthro,它可以从一张手掌朝上、置于美国信纸尺寸纸张上的智能手机照片中估计44个投影手部尺寸。该流程重建被手腕遮挡的纸张边界以进行校正,将非手部像素变白,并利用图像特定的几何形状和轮廓,从微调后的You Only Look Once(YOLO)姿态模型中细化41个特定于人体测量的关键点。受控评估包括来自45名留出参与者的720次拍摄,每名参与者贡献16张图像,涵盖两部智能手机、两种背景、两个角度和两种标称光照设置。HandAnthro对704次拍摄(97.8%)生成了完整输出;其中,与两名训练有素的操作员的卡尺测量相比,每个维度的平均绝对误差(MAE)为3.80毫米。区域MAE分别为:非拇指手指2.48毫米、拇指6.04毫米、手掌和手腕6.17毫米。在研究者辅助的移动应用试点中,自动批量处理为268张经研究者筛选的消防员图像中的260张(97.0%)返回了全部44个尺寸。与一个独立的全国消防员参考值进行的描述性非配对比较显示,在28个性别×维度组均值对比中,平均绝对差异为2.40毫米。这些结果表征了受控测量性能和研究者辅助的现场可行性,为未来分布式手部人体测量研究提供了依据。

英文摘要

Hand anthropometry supports protective-glove design, but existing measurement methods often require trained operators, specialized hardware, or manual landmarking. We present HandAnthro, which estimates 44 projected hand dimensions from a smartphone photograph of a palm-up hand on US letter-size paper. The pipeline reconstructs wrist-occluded paper boundaries for rectification, whitens non-hand pixels, and refines 41 anthropometry-specific landmarks from a fine-tuned You Only Look Once (YOLO) pose model using image-specific geometry and contours. Controlled evaluation comprised 720 captures from 45 held-out participants, each contributing 16 images across two smartphones, two backgrounds, two angles, and two nominal illumination settings. HandAnthro produced complete outputs for 704 captures (97.8%); among these, mean absolute error (MAE) was 3.80 mm per dimension against two trained operators' caliper measurements. Regional MAEs were 2.48 mm for non-thumb fingers, 6.04 mm for thumbs, and 6.17 mm for palm and wrist. In a researcher-assisted mobile-app pilot, automated batch processing returned all 44 dimensions for 260 of 268 retained, researcher-screened firefighter images (97.0%). A descriptive, unpaired comparison with an independent national firefighter reference yielded a mean absolute difference of 2.40 mm across 28 sex-by-dimension group-mean contrasts. These results characterize controlled measurement performance and researcher-assisted field feasibility for future distributed hand-anthropometry studies.

Comments21 pages, including 7 pages of main text and references and 14 pages of supplementary material

论文原文

arXiv 摘要页 · PDF 原文 · HTML 原文

↑