arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2607.03017cs.RO
收藏

超越启发式方法:用于人在回路仿真中物理人机交互的标准化真实到仿真管道

Beyond Heuristics: A Standardized Real2Sim Pipeline for Physical Human Robot Interaction in Human-in-the-Loop Simulation

School of Mechanical and Aerospace Engineering, Nanyang Technological University(南洋理工大学机械与航天工程学院);Guangdong Zhongxin Intelligent Rehabilitation Research Institute(广东众鑫智能康复研究院)

Chengyuan Yang, Yifan Wang, Chun Kwang Tan, Sherwin Stephen Chan, Youlong Wang, Xiaoyue Yan, Lei Li, Wei Tech Ang

AI总结:

研究针对人在回路仿真中交互模型阻抗参数靠启发式调整的问题,提出Real2Sim管道,用协方差矩阵自适应进化策略识别动力学参数,提高仿真保真度,支持人体数字双胞胎用于个性化控制器临床前验证。

摘要:

全球人口老龄化推动了对辅助机器人的需求,然而物理测试的安全风险和成本使得人在回路(HITL)仿真成为有吸引力的替代方案。但是,其对耦合系统的保真度受到交互模型的限制,其阻抗参数是通过启发式调整而不是从数据中识别出来的。我们提出了一种Real2Sim管道,该管道可以识别地面移动平衡辅助装置上骨盆-束带接口的耦合物理人机交互(pHRI)动力学。该接口被建模为一个6自由度的粘弹性机构,其12个方向的刚度和阻尼参数通过协方差矩阵自适应进化策略(CMA-ES)针对每个受试者进行识别,使用用户的“安全和舒适”反馈作为一个可重复的操作点,解决了不同人体测量学之间束带紧度的模糊性。对一个五名受试者的队列进行的组内相关性分析将可共享参数与特定于受试者的参数分开,从而产生一组从现有数据中得出的先验参数。部署此先验参数只需调整12个参数中的5个即可配置一个以前未见过的受试者。然后,校准后的模型会再现真实的交互包络,并在人体数字双胞胎(HDT)中诱导出生物力学上准确的步态适应。相比之下,过于柔顺和过于僵硬的设置作为极端设置会失败,这证实了一个正确的操作点,而没有任何启发式调整程序能够可靠地选择该操作点。因此,该管道提高了HITL仿真保真度,并支持人体数字双胞胎作为个性化控制器临床前验证的预测工具。

英文摘要:

The aging global population drives demand for assistive robots, yet the safety risks and costs of physical testing make Human-in-the-Loop (HITL) simulation an attractive alternative. Its fidelity for coupled systems, however, is limited by interaction models whose impedance parameters are tuned heuristically rather than identified from data. We present a Real2Sim pipeline that identifies the coupled Physical Human-Robot Interaction (pHRI) dynamics of a pelvis--strap interface on an overground mobile balance assistant. The interface is modeled as a 6-DoF viscoelastic mechanism whose 12 directional stiffness and damping parameters are identified per subject via Covariance Matrix Adaptation Evolution Strategy (CMA-ES), using the user's ``Safe \& Comfortable'' feedback as a reproducible operating point that resolves harness-tightness ambiguity across anthropometrics. An intraclass-correlation analysis over a five-subject cohort separates shareable from subject-specific parameters, yielding a set of prior parameters derived from the existing data. Deploying this prior configures a previously unseen subject by refining only 5 of the 12 parameters. The calibrated model then reproduces the real interaction envelope and induces biomechanically accurate gait adaptations in the Human Digital Twin (HDT). Overly compliant and overly stiff settings, by contrast, fail as extreme settings, confirming a correct operating point that no heuristic tuning procedure can reliably select. The pipeline thus improves HITL simulation fidelity and supports the Human Digital Twin as a predictive tool for pre-clinical verification of personalized controllers.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑