AI总结:

提出NGSE-Corr技术,通过假设线性随机关系并利用最大似然估计噪声-斜率比,实现无金标准下客观评估和排序定量成像方法。

摘要:

基于定量成像(QI)方法测量真实值的可靠性进行客观评估对于临床转化至关重要。使用患者数据进行此类评估非常理想,但缺乏金标准阻碍了其实现。为应对这一挑战,在先前研究基础上,我们提出了一种无金标准评估技术NGSE-Corr,可在无真实值的情况下客观评估QI方法。该技术假设真实值与测量值之间存在线性随机关系,由斜率、偏差和多元高斯分布噪声项(模拟QI方法间的相关噪声)表征。我们推导出一种最大似然方法,仅使用测量值估计这些参数。根据估计值,我们计算噪声-斜率比(NSR)以基于精度对QI方法进行排序。数值实验表明,NGSE-Corr能可靠估计NSR,准确排序方法,即使技术假设部分违反时仍保持性能。我们还在一项硅成像试验中验证了NGSE-Corr,用于排序三种定量SPECT方法,这些方法用于测量接受镭-223治疗的骨转移性去势抵抗性前列腺癌患者的区域活性摄取。NGSE-Corr正确识别了最精确的QI方法,并在50名患者数据下分别对95%(95% CI, 89%-98%)和91%(95% CI, 84%-95%)的试验进行了方法排序。随着队列增大,性能进一步提升。在200名患者时,NGSE-Corr在所有试验实例中均获得了与使用真实值相同的排序。这些结果表明NGSE-Corr能够在无金标准情况下准确排序QI方法,并推动临床验证和更广泛应用。

英文摘要:

Objective evaluation of quantitative-imaging (QI) methods based on how reliably they measure true values is important for clinical translation. Performing such evaluation with patient data is highly desirable but hindered by the lack of gold standards. To address this challenge, advancing on previous studies, we propose a no-gold-standard evaluation technique, NGSE-Corr, that objectively evaluates QI methods without true values. The technique assumes a linear stochastic relationship between true and measured values, characterized by a slope, bias, and multivariate Gaussian-distributed noise term that models correlated noise across QI methods. We derive a maximum-likelihood approach to estimate these parameters using only measured values. From the estimates, we compute noise-to-slope ratio (NSR) to rank QI methods based on precision. Numerical experiments showed that NGSE-Corr reliably estimated the NSR, accurately ranked methods, and maintained performance even when assumptions made by the technique were partially violated. We also validated NGSE-Corr in an in silico imaging trial to rank three quantitative SPECT methods for measuring regional activity uptake in patients with bone metastatic castrate-resistant prostate cancer treated with radium-223. NGSE-Corr correctly identified the most precise QI method and ranked the methods for 95% (95% CI, 89%-98%) and 91% (95% CI, 84%-95%) of trials, respectively, with data from 50 patients. Performance further improved with larger cohorts. With 200 patients, NGSE-Corr yielded same rankings as those obtained with true values across all trial instances. These findings demonstrate the ability of NGSE-Corr to accurately rank QI methods without gold standards and motivate clinical validation and broader applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑