arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2606.27064nucl-exphysics.ins-det
收藏

$^{110}$Sn、$^{113}$Sn、$^{117\mathrm{m}}$Sn 和 $^{123\mathrm{m}}$Sn 通过天然锡的光子活化产生的半衰期测量

Half-Life Measurements of $^{110}$Sn, $^{113}$Sn, $^{117\mathrm{m}}$Sn, and $^{123\mathrm{m}}$Sn Produced via Photon Activation of Natural Tin

NorthStar Medical Radioisotopes, LLC(北星医疗放射性同位素有限责任公司)

O Nusair, D Devries, M Toto-Gonzalez

AI总结:

通过光子活化天然锡产生四种锡同位素,利用HPGe探测器测量γ射线谱,精确测定半衰期,发现$^{117\mathrm{m}}$Sn与推荐值存在显著偏差。

摘要:

我们报告了通过使用 TT-300HE Rhodotron 加速器对天然锡进行光子活化产生的 $^{110}$Sn、$^{113}$Sn 的基态半衰期以及同质异能态 $^{117\mathrm{m}}$Sn (J$^{\pi} = 11/2^{-}$) 和 $^{123\mathrm{m}}$Sn (J$^{\pi} = 3/2^{+}$) 的独立测定。活化样品使用高纯锗 (HPGe) 探测器监测数月。利用高斯峰拟合对 $\SI{280.49}{keV}$、$\SI{391.697}{keV}$、$\SI{158.56}{keV}$ 和 $\SI{160.34}{keV}$ 跃迁的时间相关 $\gamma$ 射线谱进行分析,得到 $^{110}$Sn 的半衰期为 $\SI{4.165(25)}{h}$,$^{113}$Sn 为 $\SI{116.08(94)}{d}$,$^{117\mathrm{m}}$Sn 为 $\SI{13.95(1)}{d}$,$^{123\mathrm{m}}$Sn 为 $\SI{39.95(12)}{min}$。对于 $^{110}$Sn、$^{113}$Sn 和 $^{123\mathrm{m}}$Sn,与核数据表 (NDS) 推荐值总体一致,当使用标准化差异 (z 分数) 量化时,偏差在组合不确定度内一致。相比之下,$^{117\mathrm{m}}$Sn 显示出与评估值 $\SI{13.76(4)}{d}$ 的统计显著偏差,z 分数表明差异远超预期统计波动。这一结果表明存在系统差异,需要进一步研究,对依赖精确衰变数据的应用(包括校准、剂量测定和天体物理建模)具有潜在影响。

英文摘要:

We report independent determinations of the ground-state half-lives of $^{110}$Sn, $^{113}$Sn, and the isomeric states $^{117\mathrm{m}}$Sn (J$^π = 11/2^{-}$) and $^{123\mathrm{m}}$Sn (J$^π = 3/2^{+}$), produced via photon activation of natural tin using a TT-300HE Rhodotron accelerator. The activated samples were monitored over several months using a high-purity germanium (HPGe) detector. Time-dependent $γ$-ray spectra were analyzed using Gaussian peak fitting for the \SI{280.49}{keV}, \SI{391.697}{keV}, \SI{158.56}{keV}, and \SI{160.34}{keV} transitions, yielding half-lives of \SI{4.165(25)}{h} for $^{110}$Sn, \SI{116.08(94)}{d} for $^{113}$Sn, \SI{13.95(1)}{d} for $^{117\mathrm{m}}$Sn, and \SI{39.95(12)}{min} for $^{123\mathrm{m}}$Sn. Agreement with Nuclear Data Sheets (NDS) recommended values is generally observed for $^{110}$Sn, $^{113}$Sn, and $^{123\mathrm{m}}$Sn, with deviations consistent within combined uncertainties when quantified using standardized differences (z-scores). In contrast, $^{117\mathrm{m}}$Sn exhibits a statistically significant deviation from the evaluated value of \SI{13.76(4)}{d}, with a z-score indicating a discrepancy well beyond expected statistical fluctuations. This result suggests a systematic difference warranting further investigation, with potential implications for applications relying on precise decay data, including calibration, dosimetry, and astrophysical modeling.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑