arXivDaily arXiv每日学术速递 周一至周五更新
​通知:联邦节假日调休:哥伦布日 / 原住民日(Columbus Day / Indigenous Peoples' Day),今日(13日)无更新。
arXiv 2606.23879eess.IVcs.AI

使用对比非配对图像翻译从非增强CT扫描中进行心脏腔室分割的前景与挑战:一项可行性研究

Promise and challenges of heart chamber segmentation from non-contrast CT scans using contrastive unpaired image translation: a feasibility study

Department of Radiology, University of Pittsburgh(匹兹堡大学放射科部门);Department of Bioengineering, University of Pittsburgh(匹兹堡大学生物工程部门);Department of Ophthalmology, University of Pittsburgh(匹兹堡大学眼科学部门)

Jing Wang, Tong Yu, Hao-En Lu, Zixue Zeng, Joseph K. Leader, Xin Meng, Jianbing Zhu, Jiantao Pu

AI总结:

提出ChameleonNet框架,利用对比非配对翻译生成非增强CT,结合深度学习分割心脏四腔,在合成图像上DSC达0.91-0.94,但真实CT上体积误差较大,需进一步改进。

摘要:

目的:评估使用对比非配对图像翻译和基于深度学习的分割方法从非增强CT扫描中进行心脏腔室分割的可行性和挑战。方法:我们开发了ChameleonNet框架,该框架利用带有解耦对比学习损失的对比非配对翻译网络从增强CT扫描合成非增强CT。使用来自增强扫描的四个心脏腔室(左心房、左心室、右心房、右心室)的标注,我们在合成的非增强图像上训练了Hausdorff距离损失增强的nnU-Net。翻译模型使用35,538张增强CT切片和37,197张非增强CT切片进行训练。分割模型使用292张合成的非增强扫描进行训练。性能通过Dice相似系数和95th Hausdorff距离在36张合成非增强扫描上评估,并通过Pearson相关性、平均绝对百分比误差和平均百分比误差在36张真实非增强CT扫描上评估体积一致性。结果:分割模型在合成非增强图像上对左心房、左心室、右心房、右心室分别实现了DSC为0.94(0.01)、0.91(0.04)、0.92(0.03)、0.93(0.02),HD95为3.63(1.49)、5.74(4.08)、5.18(1.77)、5.51(3.21)毫米。在真实非增强CT扫描上,Pearson相关性分别为0.93、0.82、0.87和0.89(所有p<0.001),MAPE范围为9.22%至20.79%,MPE范围为-12.52%至4.67%。结论:ChameleonNet展示了在无需手动非增强标注的情况下从非增强CT进行心脏腔室分割的可行性。然而,体积误差,特别是左心室和右心室的误差,表明在临床使用前需要进一步改进和验证。

英文摘要:

Purpose: To evaluate the feasibility and challenges of heart chamber segmentation from non-contrast CT scans using contrastive unpaired image translation and deep learning-based segmentation. Approach: We developed ChameleonNet, a framework utilizing the Contrastive Unpaired Translation (CUT) network with decoupled contrastive learning (DCL) loss to synthesize non-contrast CT from contrast CT scans. Using annotations of four heart chambers (left atrium (LA), left ventricle (LV), right atrium (RA), and right ventricle (RV)) from contrast scans, we trained a Hausdorff distance loss-enhanced nnU-Net on synthesized non-contrast images. The translation model was trained with 35,538 contrast-enhanced and 37,197 non-contrast CT slices. The segmentation model was trained with 292 synthesized non-contrast scans. Performance was evaluated using Dice similarity coefficient (DSC) and 95th Hausdorff distance (HD95) on 36 synthesized non-contrast scans, and volume agreement on 36 real non-contrast CT scans was assessed using Pearson correlation, mean absolute percentage error (MAPE), and mean percentage error (MPE). Results: The segmentation model achieved DSC of 0.94 (0.01), 0.91 (0.04), 0.92 (0.03), 0.93 (0.02), and HD95 of 3.63 (1.49), 5.74 (4.08), 5.18 (1.77), 5.51 (3.21) mm on synthesized non-contrast images for LA, LV, RA, and RV, respectively. On real non-contrast CT scans, Pearson correlations were 0.93, 0.82, 0.87, and 0.89 (all p<0.001), with MAPE ranging from 9.22% to 20.79%, and MPE ranging from -12.52% to 4.67%. Conclusions: ChameleonNet demonstrated feasibility for heart chamber segmentation from non-contrast CT without manual non-contrast annotations. However, volume errors, particularly for LV and RV, indicate that further refinement and validation are needed before clinical use.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑