arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2606.23533cs.AI
收藏

POTracker:优化大语言模型以生成符合标准的停电报告

POTracker: Optimizing Large Language Models for Standard-Compliant Power Outage Report Generation

Iowa State University(爱荷华州立大学)

Hung Phan, Aniroop Naladala, Dubey Avanindra, Supryia Chinthavali, Lunga Dalton, Ali Jannesari

AI总结:

提出POTracker,通过新损失函数POTrackerLoss同时优化文本相似度和结构相似度,微调Qwen2.5-7B-Instruct生成符合美国电力行业标准的停电报告,结构准确率达86.47%。

摘要:

近期的大型语言模型(LLM)在通用文本生成方面表现出色,但在特定领域的数据生成中仍难以应用,因为输出必须遵循严格的格式和结构规则。与问答或翻译等开放式任务不同,特定领域的生成必须既语义正确,又符合现有指南和标准。在这项工作中,我们研究了美国公用事业停电报告的全国互操作性问题。实践中,停电报告需要是机器可读的(例如JSON或XML),并且必须严格遵循能源行业监管机构的要求。为了解决这个问题,我们提出了POTracker,一种用于停电报告生成的优化LLM。我们使用提出的目标对Qwen2.5-7B-Instruct进行微调。关键贡献是一个新的损失函数POTrackerLoss,它同时考虑了生成报告与真实报告之间的文本相似度和结构(标签)相似度。我们在一个包含1000份停电报告的数据集上评估了POTracker,并将其与五种著名的微调方法和一种基于规则的XML转换方法进行了比较。结果表明,POTracker优于其他微调方法,总体准确率提高了51%,生成停电报告的结构准确率达到86.47%。此外,我们进行了一项人工研究来评估真实标准报告的质量,领域专家对生成的标签在0-5分制上给出了平均4.03分的评分。

英文摘要:

Recent large language models (LLMs) are good at general text generation, but it is still hard to use them for domain-specific data generation because the output must follow strict formatting and structural rules. Unlike open-ended tasks such as question answering or translation, domain-specific generation must be both semantically correct and compliant with existing guidelines and standards. In this work, we study the nationwide interoperability problem of utility power outage reports in the United States. In practice, outage reports need to be machine-readable (e.g., JSON or XML) and must strictly follow requirements from energy-sector regulatory bodies. To address this problem, we propose POTracker, an optimized LLM for power outage report generation. We fine-tune Qwen2.5-7B-Instruct using our proposed objective. The key contribution is a new loss function, POTrackerLoss, that considers both textual similarity and structural (tag) similarity between the generated report and the ground-truth report. We evaluate POTracker on a dataset of 1,000 power outage reports and compare it with five well-known fine-tuning methods and one rule-based XML conversion method. Results show that POTracker outperforms other fine-tuning approaches, improving overall accuracy by up to 51% and reaching 86.47% structural accuracy for generated power outage reports. In addition, we conduct a human study to assess the quality of the ground-truth standard reports, where domain experts assign the generated labels an average score of 4.03 on a 0--5 scale.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑