基于智能手表IMU的全身高尔夫挥杆运动学重建
Full-Body Golf Swing Kinematic Reconstruction From a Smartwatch IMU
AI总结:
提出一种单手腕IMU方法(WIT-KinNet),通过时间运动编码学习手腕到全身关节角度映射,实现高尔夫挥杆全身运动学估计,平均绝对误差8.11°。
摘要:
高尔夫挥杆的定量测量对于评估技术和提供个性化反馈至关重要。然而,现有方法在高尔夫球场上使用不切实际:光学运动捕捉受限于实验室,基于摄像头的方法需要不切实际的摄像头布置,多传感器惯性测量单元(IMU)系统需要多段设置和校准。因此,我们提出了一种单手腕佩戴IMU的方法来估计高尔夫挥杆过程中的全身关节角度。所提出的Wrist-IMU Temporal Kinematic Network(WIT-KinNet)利用特定模态的IMU嵌入和时间运动编码来学习手腕到身体的运动依赖关系,并估计高尔夫挥杆过程中的全身关节角度。36名高尔夫球手(包括初学者和熟练球手)使用七种球杆类型(1号木杆、3号木杆、5号混合杆、5号铁杆、7号铁杆、9号铁杆和沙坑杆)进行了全挥杆、半挥杆和四分之一挥杆。使用同步的智能手表IMU数据和从光学运动捕捉系统导出的地面真实运动学,在受试者交叉验证下评估了所提出的WIT-KinNet。该方法在全身关节角度上实现了8.11 ± 1.84°的平均绝对误差。骨盆旋转和上躯干旋转观察到高时间相关性(r分别为0.98和0.97),X因子和S因子也显示出强相关性(r均为0.96)。误差的线性混合效应模型显示,挥杆幅度、技能水平和球杆类型均显著影响测量差异(p < 0.05)。结果建立了第一个单手腕佩戴IMU方法用于估计全身高尔夫挥杆运动学,使得在实际比赛中进行挥杆分析成为可能。
英文摘要:
Quantitative measurement of the golf swing is critical for evaluating technique and enabling individualized feedback. However, existing methods are impractical to use on the golf course: optical motion capture is laboratory-bound, camera-based methods require impractical camera placement, and multi-sensor inertial measurement unit (IMU) systems require multi-segment setup and calibration. We thus propose a single wrist-worn IMU approach for estimating full-body joint angles during golf swings. The proposed Wrist-IMU Temporal Kinematic Network (WIT-KinNet) combines IMU embedding, feature-wise linear modulation (FiLM), and temporal convolutional encoding. Thirty-six golfers, comprising beginner and skilled players, performed full, half, and quarter swings using seven club types: driver, 3-wood, 5-hybrid, 5-iron, 7-iron, 9-iron, and sand wedge. The proposed WIT-KinNet was evaluated under subject-wise cross-validation using synchronized smartwatch IMU data and ground-truth kinematics derived from an optical motion capture (OMC) system, with OMC-free IMU calibration and IMU-based swing segmentation. The proposed approach achieved a mean absolute error of $8.53\pm2.05^\circ$ across full-body joint angles. High temporal correlation was observed for pelvic rotation and upper torso rotation ($r=0.99$ for both), with X-factor and S-factor also showing strong correlations ($r=0.97$ for both). Linear mixed-effects models of the error revealed that swing amplitude significantly affected estimation error across all five trunk--pelvis variables ($p<0.05$). The results demonstrate the feasibility of full-body golf swing kinematic estimation from a commercial smartwatch, providing a potential solution for post-swing biomechanical analysis.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。