针对Carruthers GCI仪器辐射标定需求,提出基于CALSPEC标准星库的算法驱动星选方法,通过反演观测流量约束通带,仿真验证反演误差<7%。

摘要:

Carruthers Geocorona天文台是NASA首个致力于研究地球外逸层基本性质的任务。其主载荷GeoCoronal Imager由两个共对准的宽带光度成像仪组成,支持同时、共体积感测外逸层氢原子的紫外发射。然而,精确参数反演需要仪器波长依赖响应度的精确知识。为此,该任务旨在对恒星进行光度测量,并反演观测流量以约束最终通带。一个客观的、算法驱动的排序标准从与CALSPEC标准关联的精炼紫外恒星光谱库中识别出最佳观测星子集。整个工作流程——包括光谱库、通带反演和选择标准——使用合成生成的恒星测量数据进行验证,结果表明所提出的反演算法具有高恢复保真度,两个主要Lyman-alpha科学通道的通带误差率均低于7%。

英文摘要:

The Carruthers Geocorona Observatory is NASA's first mission dedicated to investigating the fundamental nature of Earth's exosphere and its dynamic response to space weather. Its primary payload, the GeoCoronal Imager, consists of two co-aligned broadband photometric imagers that support simultaneous, common-volume sensing of ultraviolet emission at 121.6 nm (Lyman-alpha) by exospheric hydrogen atoms. Accurate exospheric parameter retrieval from these images requires accurate knowledge of the instrument's optical responsivity, which enables conversion of measured exospheric signal rates into the scientifically relevant quantity of emission radiance. The Carruthers mission achieves absolute sensitivity calibration through the acquisition of photometric measurements of stars and subsequent inversion of the observed fluxes to retrieve the wavelength-dependent responsivity across the passband for each imaging configuration. The retrieval algorithm performance is enhanced by its incorporation of an objective, algorithm-driven ranking criterion to systematically select target calibration stars from a stellar spectral library. The end-to-end workflow, from the stellar selection criterion to the passband inversion, is validated using synthetically generated stellar measurements. These validation tests establish that our optical responsivity retrieval approach has high recovery fidelity, achieving error rates of <5% at the Lyman-alpha wavelength for all primary science imaging modes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑