摘要:
各向异性体积采集在临床MRI和体积电子显微镜(vEM)中很常见,其中稀疏的跨平面采样产生厚切片或截面,降低了正交重切和下游分析的质量。我们提出CRIS,一种跨平面自监督框架,无需配对各向同性真值即可实现各向同性恢复。CRIS将3D恢复视为各向同性网格正交重切上的2D条带补全:训练时,高分辨率面内切片被合成退化并周期性掩蔽;推理时,空白切片定义各向同性网格,恢复两个正交重切,并通过多视图平均融合预测。我们在两个MRI队列和两个显微镜基准上评估CRIS,各向异性高达8倍。在脑MRI上,CRIS达到32.921±0.436 dB PSNR和0.9631±0.0027 SSIM,优于插值、SMORE4、SIMPLE、SA-INR和ATME,并给出最佳分割一致性(Dice 0.940±0.004,ASSD 0.245±0.014 mm,HD99 1.275±0.061 mm)。在无参考腹部MRI上,CRIS将FID/KID降至48.714/0.023。在vEM上,CRIS优于插值、NIIV和vEMINR,在4倍时达到29.133 dB/0.834 3D PSNR/SSIM,在EPFL 8倍时达到27.123 dB/0.734,在噪声hemibrain数据上达到21.915 dB/0.699。在鲁棒性实验中,一个可变间隙CRIS模型在间隙因子3-7以及冠状、轴向和矢状退化下评估,保持比插值更高的PSNR/SSIM(36.36-31.14 dB和0.977-0.932对比33.07-27.85 dB和0.951-0.853)。这些结果支持CRIS作为一种模态灵活的途径,无需配对各向同性目标或特定配置的重新训练即可实现各向同性恢复。代码可在https://github.com/adi-hatav/CRIS获取。
英文摘要:
Anisotropic volumetric acquisitions are common in clinical MRI and volume electron microscopy (vEM), where sparse through-plane sampling creates thick slices or sections that degrade orthogonal reformats and downstream analysis. We present CRIS, a cross-plane self-supervised framework for isotropic restoration without paired isotropic ground truth. CRIS casts 3D restoration as 2D stripe completion on orthogonal reformats of an isotropic grid: high-resolution in-plane slices are synthetically degraded and periodically masked for training, while at inference blank slices define the isotropic grid, two orthogonal reformats are restored, and predictions are fused by multi-view averaging. We evaluate CRIS on two MRI cohorts and two microscopy benchmarks up to 8x anisotropy. On brain MRI, CRIS achieves 32.921 +/- 0.436 dB PSNR and 0.963 +/- 0.003 SSIM, outperforming interpolation, ECLARE, SMORE4, SIMPLE, SA-INR, and ATME, and gives the best segmentation consistency (Dice 0.940 +/- 0.004, ASSD 0.245 +/- 0.014 mm, HD99 1.275 +/- 0.061 mm). On reference-free abdominal MRI, CRIS reduces FID/KID to 48.71/0.023, outperforming interpolation, ECLARE, SMORE4, and SIMPLE. On vEM, CRIS achieves 29.100 dB/0.830 3D PSNR/SSIM at 4x and 26.874 dB/0.722 at 8x on EPFL, and 21.935 +/- 0.437 dB/0.696 +/- 0.024 on noisy hemibrain data. In a dedicated robustness experiment, one variable-gap CRIS model evaluated across gap factors 3-7 and coronal, axial, and sagittal degradations maintained higher PSNR/SSIM than interpolation (36.36-31.14 dB and 0.977-0.932 vs. 33.07-27.85 dB and 0.951-0.853). These results support CRIS as a modality-flexible route to isotropic restoration without paired isotropic targets or configuration-specific retraining. Code is available at https://github.com/adi-hatav/CRIS.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。