arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2606.07192physics.flu-dynphysics.med-ph
收藏

空间异质性黏蛋白覆盖对泪膜稳定性和破裂的影响

Effect of Spatially Heterogeneous Mucin Coverage on Tear Film Stability and Ruptur

Indian Institute of Technology Madras(印度马德拉斯理工学院)

Deepak Kumar, Pushpavanam S

AI总结:

通过薄膜模型研究角膜表面异质性润湿性对泪膜稳定性的影响,发现黏蛋白缺乏区域优先破裂,破裂位置由分离压分布决定,模型预测的破裂时间与临床值吻合。

摘要:

干眼的临床观察表明,泪膜破裂与非均匀黏蛋白覆盖引起的角膜润湿性空间变化有关。受这些观察启发,我们开发了一个薄膜模型来研究异质性润湿性对泪膜稳定性的影响。黏蛋白覆盖的异质性通过角膜表面哈马克常数和滑移长度的变化来体现。考虑了两种代表性的空间异质性形式:代表尖锐局部黏蛋白缺乏区域的周期性阶跃变化,以及代表糖萼逐渐变化的平滑正弦分布。稳态由毛细力和范德华力之间的平衡获得。基于Floquet-Bloch理论和离散特征值方法的线性稳定性框架被开发出来,以解释线性化方程中的周期系数。我们表明,异质性润湿性诱导了扰动模式之间的耦合。最不稳定波数和最大增长率随黏蛋白覆盖分数的增加而减小。然而,两者都随黏蛋白丰富和缺乏区域之间哈马克常数对比度的增加而增加。非线性模拟显示,无论初始膜厚度如何,破裂优先定位于黏蛋白缺乏区域。破裂位置由分离压的空间分布而非初始扰动决定。预测的破裂动力学与临床观察一致,其中破裂位置不变,模型获得的破裂时间与临床报告值吻合良好。这些发现表明,润湿性的空间异质性在泪膜不稳定性中起决定性作用,必须纳入泪膜动力学模型。

英文摘要:

Clinical observations of dry eyes reveal that tear film breakup is associated with spatial variations in corneal wettability arising from non-uniform mucin coverage. Motivated by these observations, we develop a thin-film model to investigate the influence of heterogeneous wettability on tear film stability. Heterogeneity in mucin coverage is incorporated through variations in the Hamaker constant and slip length along the corneal surface. Two representative forms of spatial heterogeneity are considered: a periodic step variation representing sharply localised mucin-deficient patches and a smoothly varying sinusoidal distribution representing gradual changes in glycocalyx. The steady states are obtained by a balance between capillary and van der Waals forces. A linear stability framework based on Floquet-Bloch theory and a discretised eigenvalue approach is developed to account for the periodic coefficients in the linearised equations. We show that heterogeneous wettability induces coupling between perturbation modes. The most unstable wavenumber and the maximum growth rate decrease with increasing mucin coverage fraction. However, both increase with increasing Hamaker constant contrast between mucin-rich and mucin-deficient regions. Nonlinear simulations reveal that rupture preferentially localises within mucin-deficient regions irrespective of the initial film thickness. The rupture location is governed by the spatial distribution of disjoining pressure rather than the initial perturbation. The predicted rupture dynamics are consistent with clinical observations where rupture location is invariant and the rupture times obtained from the model are in good agreement with clinically reported values. These findings demonstrate that spatial heterogeneity in wettability plays a decisive role in tear film instability and must be incorporated in tear film dynamics models.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑