模板坍塌与相机rPPG脉搏形态恢复中的信息论极限
Template Collapse and Information-Theoretic Limits in Camera rPPG Pulse Morphology Restoration
AI总结:
本研究通过评估16种架构在153名受试者上的表现,引入跨受试者Pearson r来区分个体特异性恢复与模板坍塌,发现消费者摄像头无法编码个体动脉形态,且无架构能恢复个体特异性脉搏形态。
摘要:
目的:消费者面部相机远程光电容积描记法(rPPG)可实现被动心血管监测,但单周期波形形态(编码动脉硬化生物标志物)是否可从该测量中恢复尚未明确。方法:我们在三个数据集的153名受试者上评估了涵盖六个家族的16种架构,引入跨受试者Pearson r以区分个体特异性恢复与模板坍塌。结果:无架构恢复个体特异性形态(跨受试者r范围0.773--0.9999;真实上限0.601)。监督对比学习(SupCon)收敛至log N = 4.844,构成现有最强经验证据,表明测试的编码器家族无法从单周期rPPG中提取可判别形态结构。VAE解码器恢复了rPPG输入中缺失的群体级谐波内容(H2/H1:输出0.310 vs. 输入0.275),零样本泛化至UBFC(r = +0.708);方向性幻觉差距(p = 0.150)提示部分信号读取。当输入不携带可判别结构时,抗坍塌目标失效。意义:消费者摄像头无法编码个体动脉形态;跨受试者r是波形重建基准中必要的坍塌诊断指标。
英文摘要:
Objective: Consumer face camera remote photoplethysmography (rPPG) enables passive cardiovascular monitoring, but whether single-cycle waveform morphology encoding arterial stiffness biomarkers is recoverable from this measurement has not been characterised. Methods: We evaluated 16 architectures spanning six families on 153 subjects across three datasets, introducing cross-subject Pearson r to distinguish subject-specific recovery from template collapse. Results: No architecture recovered subject-specific morphology (cross-subject r range 0.773--0.9999; ground-truth ceiling 0.601). Supervised Contrastive (SupCon) converged to log N = 4.844, constituting the strongest available empirical evidence that no discriminative morphological structure is extractable from single-cycle rPPG by the encoder families tested. The VAE decoder restores population-level harmonic content absent from the rPPG input (H2/H1: 0.310 output vs. 0.275 input), generalising zero-shot to UBFC (r = +0.708); a directional hallucination gap (p = 0.150) suggests partial signal reading. Anti-collapse objectives fail when input carries no discriminative structure. Significance: Consumer cameras cannot encode individual arterial morphology; cross-subject r is a necessary collapse diagnostic for waveform reconstruction benchmarks.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。