arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2606.02276cs.CVcs.AIcs.CLcs.LG
收藏

临床视觉-语言模型中的跨模态链接风险

Selective Linkage Precision for Released Medical Vision-Language Models

Lab for AI in Medicine(医学人工智能实验室);RWTH Aachen University(亚琛工业大学);Department of Diagnostic and Interventional Radiology(诊断与介入放射学部门)

Soroosh Tayebi Arasteh, Mahshad Lotfinia, Sven Nebelung, Daniel Truhn

AI总结:

研究临床视觉-语言模型(VLM)在图像与报告分离场景下通过余弦相似度实现跨模态重链接的风险,并采用仅对投影头进行差分隐私微调的方法在保持图像效用同时显著降低重链接率。

摘要:

在配对胸部X光片和放射学报告上训练的视觉-语言模型(VLM)学习了一个共享嵌入空间,该空间可以保留实例级别的图像-报告对应关系。这在故意将X光片和报告在获取后分开的场景中(例如仅图像数据共享或受控访问的报告)构成了隐私风险,因为一个去标识的图像可能仅通过余弦相似度就重新链接到其原始叙述性报告。我们将此形式化为图像到报告的检索,并使用公共配对队列(其中真实配对是已知的)作为基准来审计风险,而不是作为隐私场景。在来自MIMIC-CXR(43,793个保留对)和外部CheXpert Plus(29,296个对)的126,804名患者的406,241个配对示例上评估了临床专业化程度递增的VLM,我们发现重链接率随专业化程度系统性地上升:最强的VLM在候选池N=100时以15倍随机概率检索到正确报告,在N=10,000时以50倍随机概率,在全数据库规模下仍远高于随机概率。该信号在去除疾病标签捷径的病理匹配困难负样本下仍然存在,表明对应关系超出了广泛的诊断类别。为了在不重新训练的情况下减少这种风险,我们冻结了两个编码器,仅对定义对齐层的投影头应用差分隐私优化(epsilon=0.34,delta=6x10^-6)。这使得MIMIC-CXR上N=10,000时的Recall@1降低了61.8%,并无需重新训练即可迁移到CheXpert Plus,同时图像侧效用基本保持:线性探针分类在14个标签上的宏AUROC仅从79.63%变为79.43%。对共享对齐层的定向DP微调可以大幅减少跨模态重链接,而不会实质性降低使这些模型在临床上有用的图像表示。

英文摘要:

Hospitals may release de-identified chest radiographs while restricting access to their reports. An attacker who already has reports from the same population and their metadata can use a vision-language model (VLM) to match images to reports. We introduce selective linkage precision, which measures correct matches among the highest-confidence queries after filtering candidates by the available attributes. Across 8 public VLMs and 3 chest radiograph datasets, the maximum whole-pool Recall@1 is 0.40%. However, this metric averages over every query without attribute filtering. On ReXGradient-160K, MedSigLIP-448 reaches 67.68% precision at a budget of 100 after filtering by sex, age band, and projection, with a median of 327 candidate reports. On the same eligible query set, an attribute-only policy reaches 24.99% and the model alone reaches 1.98%. Adding acquisition year, available in only 1 of the 3 datasets, yields 99.05% precision and a median of 24 candidates. Uniform guessing on the observed selected queries has an expected precision of 19.91%. Expanding the primary-setting collection to all 123,100 ReXGradient studies lowers precision to 37.23%. On BioViL-T, the tested head finetuning procedures do not lower linkage below the public checkpoint. Selective linkage precision requires inference without retraining and could help hospitals evaluate which attributes to publish.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑