arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.30623stat.AP
收藏

基于相位对比MRI的主肺动脉速度剖面不确定性感知估计的贝叶斯框架

A Bayesian Framework for Uncertainty-Aware Estimation of Main Pulmonary Artery Velocity Profiles from Phase-Contrast MRI

Edwards Lifesciences Foundation Cardiovascular Innovation and Research Center, Department of Biomedical Engineering, University of California, Irvine(加州大学尔湾分校爱德华生命科学基金会心血管创新与研究中心生物医学工程系)

Amirreza Kachabi, Naomi C. Chesler

AI总结:

提出一个贝叶斯框架,结合二维相位对比MRI和机理速度剖面公式,生成考虑不确定性的个体化肺动脉速度表示。

摘要:

计算心血管血流模型对预设的入口速度剖面高度敏感。虽然成像衍生的速度场提供了生理上真实的信息,但它们可能增加预处理复杂性、成像噪声和计算负担。简化的解析公式计算效率高,但可能无法完全捕捉个体特定的血流特征。在本研究中,我们提出了一个不确定性感知框架,将二维相位对比磁共振成像(2D PC-MRI)与机理速度剖面公式相结合,以生成个体化的肺动脉速度表示。使用椭圆径向分箱和归一化,从犬和猪受试者的主肺动脉(MPA)PC-MRI数据构建成像衍生的径向速度分布。在贝叶斯推断框架内拟合幂律和Womersley速度剖面公式,同时考虑与成像测量和模型表示相关的不确定性。使用区域和全局加权均方根误差(wRMSE)指标比较两种公式。两种模型均与受试者的成像衍生速度剖面表现出良好的一致性。尽管Womersley公式在血管壁附近提供了更大的灵活性,但与更简单的幂律模型相比,并未导致拟合性能的统计显著改善。所提出的框架提供了低维、生理可解释且具有不确定性感知的速度剖面表示,可作为个体化心血管血流建模的计算高效替代方案。

英文摘要:

Computational cardiovascular flow models are highly sensitive to prescribed inlet velocity profiles. While imaging-derived velocity fields provide physiologically realistic information, they can introduce increased preprocessing complexity, imaging noise, and computational burden. Simplified analytical formulations are computationally efficient but may not fully capture subject-specific flow characteristics. In this study, we present an uncertainty-aware framework that combines two-dimensional phase-contrast magnetic resonance imaging (2D PC-MRI) with mechanistic velocity-profile formulations to generate subject-specific pulmonary artery velocity representations. Imaging-derived radial velocity distributions were constructed from main pulmonary artery (MPA) PC-MRI data in canine and swine subjects using elliptical radial binning and normalization. Power-law and Womersley velocity-profile formulations were fitted within a Bayesian inference framework while accounting for uncertainty associated with imaging measurements and model representation. The two formulations were compared using regional and global weighted root mean square error (wRMSE) metrics. Both models demonstrated close agreement with the imaging-derived velocity profiles across subjects. Although the Womersley formulation provided greater flexibility near the vessel wall, it did not result in statistically significant improvements in fitting performance compared with the simpler power-law model. The proposed framework provides low-dimensional, physiologically interpretable, and uncertainty-aware velocity-profile representations that may serve as computationally efficient alternatives for subject-specific cardiovascular flow modeling.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑