生物燃料电池基于的ctDNA检测在血管内传感中的全血边界分析

Whole-Blood Boundary Analysis of BioFET-Based ctDNA Detection for Intravascular Sensing in Intrabody Nanonetworks

Gdansk University of Technology(格但斯克理工大学);i2Cat Foundation(i2Cat基金会);Universitat Politècnica de Catalunya(加泰罗尼亚理工大学)

Ida Kleger-Rudomin, Filip Lemic, Sergi Abadal, Eduard Alarcon, Ethungshan Shitiri

AI总结:

本文研究了生物燃料电池基纳米传感器在全血中检测循环肿瘤DNA的可行性,通过建立简化随机模拟模型,分析了操作点选择、德拜屏蔽电荷传导、随机有限容量结合、非特异性吸附、背景波动和固有电子噪声等因素对空白阈值检测的影响,揭示了哪些界面配置和操作条件最限制了可靠的生物燃料电池基于的血管内ctDNA检测。

摘要:

液体活检可以检测如循环肿瘤DNA(ctDNA)等肿瘤来源的生物标志物,但超低分数试验仍成本高、速度慢且难以扩展。这促使了在内体纳米网络背景下对血管内体外传感的兴趣,其中纳米传感器可以支持局部生物标志物监测。生物燃料电池基纳米传感器在此相关,因为它们是无标记的、高度微型化的,并且在受控介质中显示出强的ctDNA灵敏度。我们检查了这种灵敏度是否仍能在全血中产生可靠的ctDNA检测,使用了一个简化阶次随机模拟模型,该模型将操作点选择、德拜屏蔽电荷传导、随机有限容量结合、非特异性吸附、背景波动和固有电子噪声连接到空白阈值检测。蒙特卡洛评估使用生理学基础参数表明,短德拜长度和几纳米的电荷到通道分离会减弱电流变化,而低频噪声和背景波动会减少目标存在与空白响应之间的差距。在测试的准静态电荷门控状态下,模拟的电流变化在低ctDNA浓度下无法可靠地超过空白来源的阈值。因此,该模型提供了全血边界分析,识别了哪些界面配置和操作条件最限制了可靠的生物燃料电池基于的血管内ctDNA检测。

英文摘要:

Liquid biopsy can detect tumor-derived biomarkers such as circulating tumor DNA (ctDNA), but ultra-low-fraction assays remain costly, slow, and difficult to scale. This motivates interest in intravascular in vivo sensing in the context of intrabody nanonetworks, where nanosensors could support local biomarker monitoring. BioFET-based nanosensors are relevant here because they are label-free, highly miniaturizable, and have shown strong ctDNA sensitivity in controlled media. We examine whether this sensitivity still yields reliable ctDNA detection in whole blood using a reduced-order stochastic simulation model that links operating-point selection, Debye-screened charge transduction, stochastic finite-capacity binding, nonspecific adsorption, background fluctuations, and intrinsic electronic noise to blank-threshold detection. Monte Carlo evaluation with physiologically grounded parameters shows that short Debye length and several-nanometer charge-to-channel separation attenuate the current shift, while low-frequency noise and background fluctuations reduce the margin between target-present and blank responses. Under the tested quasi-static charge-gating regime, the simulated current shifts do not reliably exceed the blank-derived threshold at low ctDNA concentrations. The model therefore provides a whole-blood boundary analysis that identifies which interface configurations and operating conditions most strongly limit reliable BioFET-based intravascular ctDNA detection.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑