arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.22572cs.CV
收藏

SegGuidedNet: 基于子区域的注意力监督用于可解释性脑肿瘤分割

SegGuidedNet: Sub-Region-Aware Attention Supervision for Interpretable Brain Tumor Segmentation

German Research Center for Artificial Intelligence(德国人工智能研究中心);Intelligentx GmbH (intelligentx.com)(Intelligentx GmbH);National University of Sciences and Technology (NUST)(国家科学与技术大学);Department of Core Informatics, Graduate School of Informatics ,Osaka Metropolitan University(信息学研究生院核心信息学系,大阪 metropolitan 大学)

Hasaan Maqsood, Saif Ur Rehman Khan, Sebastian Vollmer, Andreas Dengel, Muhammad Nabeel Asim

AI总结:

本文提出SegGuidedNet,一种引入新颖SegAttentionGate模块的三维残差编码器-解码器网络,通过轻量级辅助损失显式监督解码器生成每个肿瘤子区域(坏死核心、周围水肿、增强肿瘤)的空间判别注意力图,从而在无需后处理解释方法的情况下提供免费的空间可解释性,并在BraTS2021和BraTS2023 GLI上实现了优异的分割性能。

摘要:

准确分割多参数MRI中脑肿瘤的子区域对于治疗计划至关重要,但因形态学变化、类别不平衡和不同成像序列中肿瘤区域的重叠外观而具有挑战性。我们提出了SegGuidedNet,一种引入新颖SegAttentionGate模块的三维残差编码器-解码器网络,该模块通过轻量级辅助损失显式监督解码器,为每个肿瘤子区域(坏死核心、周围水肿、增强肿瘤)生成空间判别性注意力图,参数开销低于0.2%。这种子区域监督在保持解码器在视觉模糊类别间的判别能力的同时,无需任何后处理解释方法即可在推理过程中提供免费的空间可解释性。在独立评估BraTS2021和BraTS2023 GLI的251个被排除受试者上,SegGuidedNet分别实现了平均Dice系数为0.905(ET=0.873,TC=0.906,WT=0.935)和0.897(ET=0.859,TC=0.902,WT=0.931),超越了基于集成的nnU-Net和HNF-Netv2作为单一模型,并接近Swin UNETR在2-4个Dice点内以少量推理成本实现。结果在两个基准版本中的一致性进一步验证了所提出方法的通用性,提供了一个轻量、临床实用的框架,在保证准确性的同时具备内置的可解释性。

英文摘要:

Accurate segmentation of brain tumour sub-regions from multi-parametric MRI is critical for treatment planning yet remains challenging due to morphological variability, class imbalance, and overlapping appearances of tumour regions across imaging sequences. We propose SegGuidedNet, a three-dimensional residual encoder--decoder network introducing a novel SegAttentionGate module that explicitly supervises the decoder to produce spatially discriminative attention maps for each tumour sub-region necrotic core, peritumoral oedema, and enhancing tumour via a lightweight auxiliary loss, adding less than 0.2% parameter overhead. This sub-region supervision maintains decoder discriminability between visually ambiguous classes while providing free-of-cost spatial interpretability at inference without any post-hoc explanation method. Evaluated independently on BraTS2021 and BraTS2023 GLI across 251 held-out subjects each, SegGuidedNet achieves mean Dice of 0.905 (ET= 0.873, TC=0.906, WT=0.935) and 0.897 (ET=0.859, TC=0.902, WT=0.931) respectively, surpassing ensemble-based nnU-Net and HNF-Netv2 as a single model and approaching Swin UNETR a 10-model ensemble within 2--4 Dice points at a fraction of the inference cost. The consistency of results across two benchmark editions further confirms the generalisability of the proposed approach, offering competitive accuracy with built-in interpretability in a lightweight, clinically practical framework.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑