arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.21669cs.CVcs.AI
收藏

MRecover: 一种基于AI生成对比度的条件生成模型,用于通过AI生成对比度恢复运动模糊的MRI图像

MRecover: A Conditional Generative Model for Recovering Motion-Corrupted MR images Using AI Generated Contrast

Department of Bioengineering, University of Pittsburgh(匹兹堡大学生物工程系);School of Medicine, University of Pittsburgh(匹兹堡大学医学院);Department of Radiology, University of Pittsburgh(匹兹堡大学放射科);Department of Psychiatry, University of Pittsburgh(匹兹堡大学精神病学系)
Jinghang Li, Tales Santini, Courtney Clark, Bruno de Almeida, Cong Chu, Salem Alkhateeb, Andrea Sajewski, Jacob Berardinelli, Hecheng Jin, Tobias Campos, Jeremy… 展开作者

Jinghang Li, Tales Santini, Courtney Clark, Bruno de Almeida, Cong Chu, Salem Alkhateeb, Andrea Sajewski, Jacob Berardinelli, Hecheng Jin, Tobias Campos, Jeremy J. Berardo, Joseph Mettenburg, Ariel Gildengers, Howard J. Aizenstein, Minjie Wu, Tamer S. Ibrahim

AI总结:

该研究提出了一种条件生成模型MRecover,利用AI生成的对比度来恢复运动模糊的MRI图像,通过自回归切片条件化实现体积分 consistency,提高了 hippocampal 子区域分割的精度和泛化能力。

摘要:

海马亚区分割需要高分辨率的T2w turbo spin echo (TSE) MRI,但该序列易受运动伪影影响,导致数据丢失。我们开发了一种条件生成模型(MRecover),通过自回归切片条件化生成常规获取的T1w图像,生成TSE图像以实现体积分 consistency。在7T MRI数据(n=577)上训练,该模型在域内实现了高保真度(n=148,SSIM=0.84,FSIM=0.94),并能很好地推广到域外3T数据:合成和原生图像的亚区体积高度匹配(n=416,r=0.87-0.97),并在运动影响的ADNI3数据集中通过质量控制后,分析可及受试者数量增加了31.8%(593 vs 450)。合成图像还由于增加诊断组差异的样本量,产生了更大的效应量(整个海马体ε²=0.121-0.100 vs. 0.086-0.062,左右半球)。项目页面:https://jinghangli98.github.io/MRecover/

英文摘要:

Hippocampal subfield segmentation requires high-resolution T2w turbo spin echo (TSE) MRI, yet this sequence is susceptible to motion artifacts, leading to substantial data loss. We developed a conditional generative model (MRecover) that synthesizes routinely acquired T1w images to create TSE images with autoregressive slice conditioning for volumetric consistency. Trained on 7T MRI data (n=577), the model achieved high in-domain fidelity (n=148, SSIM=0.84, FSIM=0.94) and generalized well to out-of-domain 3T data: subfield volumes from synthesized and the as-acquired images closely matched: (n=416, r=0.87-0.97) and yielded 31.8% more analyzable subjects in the motion-affected ADNI3 dataset after quality control (593 vs 450). The synthesized images also achieved larger effect sizes due to increasing the sample size for diagnostic group differences in hippocampal subfield atrophy (whole hippocampus $ε^2$= 0.121-0.100 vs. 0.086-0.062, left-right hemispheres). Project page: https://jinghangli98.github.io/MRecover/

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑