arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.12005physics.ins-det
收藏

开发和验证LNL CN Van de Graaff加速器0.7-4 MeV准单能中子能力

Development and validation of a forward 0.7--4 MeV quasi-monoenergetic neutron capability at the CN Van de Graaff of LNL

University of Cassino(卡辛诺大学);University of Padova(帕多瓦大学);INFN -- Laboratori Nazionali di Legnaro (LNL)(意大利国家核物理研究所列纳罗国家实验室);Technical University of Munich (TUM)(慕尼黑工业大学);Mizoram University(米佐拉姆大学);State University of Campinas(坎皮纳斯州立大学)
Jeffery Wyss, Pierfrancesco Mastinu, Elizabeth Musacchio González, Guido Martín Hernández, Luca Silvestrin, Alberto Monetti, Hans Th. J. Steiger, Manuel Böhles,… 展开作者

Jeffery Wyss, Pierfrancesco Mastinu, Elizabeth Musacchio González, Guido Martín Hernández, Luca Silvestrin, Alberto Monetti, Hans Th. J. Steiger, Manuel Böhles, B. Lalremruata, Saulo Gabriel Alberton, David Flechas

AI总结:

本文研究了LNL CN Van de Graaff加速器0.7-4 MeV范围内的准单能中子能力,通过比较不同传输工具和时间飞行测量,评估模型依赖性变化,并验证中子通量估算。

摘要:

INFN-LNL的CN Van de Graaff加速器通过7Li(p,n)7Be反应在薄金属锂靶上产生0.7-4 MeV范围的前向角准单能中子。本文描述了该前向中子能力的开发和实验验证,结合了常用传输工具的比较和时间飞行(ToF)测量。通过比较EPEN、FLUKA、MCNPX和PINO计算的中子产量,评估了与通量估计相关的模型依赖性变化。对于零入射能展,一组相互一致的传输计算在5%内一致,并用作归一化的实用参考。研究了入射能卷积对预测产量的影响。使用亚纳秒次级脉冲系统进行的时间飞行测量验证了准单能中子组件在探测器位置的时间结构和前向角动力学,中子到达时间与预期的前向动力学在实验分辨率内一致。利用测量的质子电流和基于该参考集的传输计算,估计了设备位置的前向中子通量,总不确定度约为9%,包括电流积分、靶厚和几何因素的贡献。一次短时间的设备辐照,与ToF活动同时进行,展示了在CN束条件下可测量的响应,并确认了该束流在低MeV中子研究中的实际可用性。这些结果确立了CN 0°前向准单能中子能力在0.7-4 MeV范围内的当前操作性能,并识别了向常规校准操作所需的步骤。

英文摘要:

The CN Van de Graaff accelerator of INFN--LNL provides forward-angle quasi-monoenergetic neutrons in the 0.7--4 MeV range via the 7Li(p,n)7Be reaction on thin metallic lithium targets. This work describes the development and experimental validation of this forward neutron capability, combining comparisons of commonly used transport tools with time-of-flight (ToF) measurements. Neutron yields calculated with EPEN, FLUKA, MCNPX, and PINO are compared over the CN energy range in order to assess model-dependent variations relevant for fluence estimates. For zero incident-energy spread, a mutually consistent set of transport calculations agrees within 5% and is used as a practical reference for normalisation. The effect of incident-energy convolution on the predicted yields is examined. Time-of-flight measurements performed using a sub-nanosecond secondary pulsing system verify the timing structure and forward-angle kinematics of the quasi-monoenergetic neutron component at the detector position, with neutron arrival times consistent with the expected forward kinematics within the experimental resolution. Using measured proton currents and transport calculations based on this reference set, forward neutron fluences at the device position are estimated with an overall uncertainty of approximately 9%, including contributions from current integration, target thickness, and geometry. A short device irradiation, carried out in parallel with the ToF campaign, demonstrates measurable response under CN beam conditions and confirms the practical usability of the beam for low-MeV neutron studies. Together, these results establish the current operational performance of the CN 0° forward quasi-monoenergetic neutron capability in the 0.7--4 MeV range and identify the steps required toward routine calibrated operation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑