arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2605.09983cs.NE
收藏

用于毫米波传感的脉冲神经网络频率匹配

Frequency Matching in Spiking Neural Networks for mmWave Sensing

College of Computer Science and Technology, Zhejiang University(浙江大学计算机科学与技术学院);School of Computer Science, Fudan University(复旦大学计算机学院);Department of Computer Science and Engineering, Southern University of Science and Technology(南方科技大学计算机科学系);California Institute of Technology(加州理工学院);School of Software Technology, Zhejiang University(浙江大学软件学院)

Di Yu, Zhenyu Liao, Changze Lv, Wentao Tong, Linshan Jiang, Sijie Ji, Xin Du, Hailiang Zhao, Xiaoqing Zheng, Shuiguang Deng

AI总结:

本文研究了脉冲神经网络在毫米波传感中的应用,通过分析LIF动态的低通滤波特性,提出了一种基于频率匹配的配置方法,提升了边缘设备的效率和准确性。

摘要:

毫米波(mmWave)传感能够实现隐私保护的持续边缘感知,但其测量通常稀疏、时间不规则且受高频噪声干扰。现有mmWave管道主要依赖人工神经网络(ANNs),通过大量预处理或深度架构实现鲁棒性,从而限制了其在边缘设备上的效率。本文从机制-数据对齐的角度研究毫米波传感中的脉冲神经网络(SNNs)。通过利用漏极整合与发火(LIF)动态的低通滤波行为,分析其隐含的时间滤波如何与毫米波信号的频率结构相互作用。分析表明,当判别信息位于低至中频时,LIF动态可以内在地抑制高频噪声,阐明了SNN为何优于ANN。基于此洞察,我们推导出一种原则性的准则,通过将LIF动态的有效带宽与数据的判别频谱内容匹配,配置膜衰减因子。在四个广泛使用的mmWave数据集上进行的实验验证了所提出的频率匹配假设,结果在统一评估协议下,平均测试准确率提高了6.22%,理论能耗减少了3.64倍相对于ANN基线。

英文摘要:

Millimeter-wave (mmWave) sensing enables privacy-preserving, always-on edge perception, but its measurements are often sparse, temporally irregular, and corrupted by high-frequency noise. Existing mmWave pipelines predominantly rely on artificial neural networks (ANNs), which achieve robustness through extensive preprocessing or deep architectures, thereby limiting their efficiency on edge devices. In this work, we study spiking neural networks (SNNs) for mmWave sensing from a mechanism-data alignment perspective. By leveraging the low-pass filtering behavior of leaky integrate-and-fire (LIF) dynamics, we analyze how their implicit temporal filtering interacts with the frequency structure of mmWave signals. Our analysis shows that when discriminative information resides in low-to-mid frequencies, LIF dynamics can inherently suppress high-frequency noise, clarifying when and why SNNs outperform ANNs. Based on this insight, we derive a principled criterion for configuring the membrane decay factor by matching the effective bandwidth of LIF dynamics to the data's discriminative spectral content. Experimental results across four widely used mmWave datasets validate the proposed frequency-matching hypothesis, yielding an average test-accuracy improvement of 6.22% and a 3.64$\times$ reduction in theoretical energy consumption relative to ANN baselines, under a unified evaluation protocol.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑