CXR-ContraBench:医疗视觉语言模型中否定选项吸引力的基准测试
CXR-ContraBench: Benchmarking Negated-Option Attraction in Medical VLMs
AI总结:
研究医疗视觉语言模型在否定选项吸引力问题上的表现,通过CXR-ContraBench基准测试发现模型在面对矛盾图像和问题时易产生极性反转,提出QCCV-Neg方法有效修复极性混淆问题。
摘要:
当胸部X光显示有浸润但问题询问哪项发现存在时,医疗视觉语言模型可能回答"无浸润"。这不仅仅是错误选择:这是极性反转,发出与图像矛盾的临床陈述。我们研究这种失败现象为否定选项吸引力,即模型在视觉证据和问题均冲突时被吸引至否定答案选项。我们引入CXR-ContraBench(胸部X光矛盾基准),涵盖内部ReXVQA切片和外部OpenI和CheXpert协议。该基准聚焦于存在性发现问题,选择"无X"尽管可见X会带来主要临床风险,并利用缺失性发现问题作为次要测试是否模型复制否定用语。在CheXpert协议中,失败现象显著且持续。在严格直接存在探测中,MedGemma和Qwen2.5-VL仅达到31.49%和30.21%的准确率;在匹配的135,754记录CheXpert训练分割协议中,两者模型在超过62%的存在问题上选择否定选项。链式推理提示减少了一些存在侧的反转,但并未消除它们且可能放大缺失侧的矛盾。最后,QCCV-Neg(问题条件一致性验证器用于否定)确定性修复测量的极性混淆子集而不重新训练,将MedGemma和Qwen2.5-VL在直接存在探测中的准确率提升至96.60%和95.32%。这些结果表明标准准确率可能隐藏具有临床意义的推理时间极性失败。源代码和基准构建脚本可在https://github.com/fangzr/cxr-contrabench-code获取。
英文摘要:
When a chest X-ray shows consolidation but the question asks which finding is present, a medical vision-language model may answer "No consolidation." This is more than an incorrect choice: it is a polarity reversal that emits a clinical statement contradicting the image. We study this failure as negated-option attraction, where a model is drawn to a negated answer option even when it conflicts with both the visual evidence and the question. We introduce CXR-ContraBench (Chest X-Ray Contradiction Benchmark), a diagnostic benchmark spanning internal ReXVQA slices and external OpenI and CheXpert protocols. The benchmark centers on present-finding questions, where selecting "No X" despite visible X creates the main clinical risk, and uses absent-finding questions as secondary tests of whether models copy negated wording. Across CheXpert protocols, the failure is substantial and persistent. On a strict direct presence probe, MedGemma and Qwen2.5-VL reach only 31.49% and 30.21% accuracy, respectively; on a matched 135,754-record CheXpert training-split protocol, both models select negated options on over 62% of presence questions. Chain-of-thought prompting reduces some presence-side reversals but does not eliminate them and can amplify absence-side contradictions. Finally, QCCV-Neg (Question-Conditioned Consistency Verifier for Negation) deterministically repairs the measured polarity-confused subset without retraining, raising MedGemma and Qwen2.5-VL to 96.60% and 95.32% accuracy on the direct presence probe. These results show that standard accuracy can hide a clinically meaningful inference-time polarity failure. Source code and benchmark construction scripts are available at https://github.com/fangzr/cxr-contrabench-code.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。