临床FLASH-RT部署中电子相空间生成边界采样伪影的表征与缓解
Characterization and Mitigation of Boundary Sampling Artifacts in Electron Phase Space Generation for Clinical FLASH-RT Deployment
AI总结:
本研究针对电子FLASH放疗中相空间记录平面与施照器界面重合导致的边界采样伪影,通过Geant4模拟表征其成因,并提出下游1 mm偏移可完全消除伪影且不影响初级束特性。
摘要:
在孔径出口记录的特定施照器相空间(PHSP)文件可将电子FLASH放射治疗的蒙特卡洛剂量计算时间减少30-50%。然而,将PHSP记录平面与施照器-空气界面重合会引入边界采样伪影。本研究在基于Geant4的模拟中表征了这些伪影并展示了其缓解方法。使用GAMOS 6.2.0为9 MeV Mobetron UHDR模型生成了PHSP文件,覆盖十二种临床孔径配置(直径2.5-10 cm)。评估了相对于物理孔径出口的三个记录平面位置:与界面重合、下游0.1 mm和下游1 mm。在精确界面处记录产生了高达2.2 mm的近端R50偏移和4-6 mm的剂量一致性(DTA)值,超出临床接受标准。伪影严重程度与孔径直径成反比,最小配置受影响最严重。0.1 mm偏移部分恢复了初级电子能谱,但未能恢复轫致辐射尾部。1 mm偏移完全解决了所有伪影,平均DTA值在2.0 mm以内,与直线加速器出口参考相当或更优。这些伪影源于fUseSafety步长限制算法在安全距离在精确材料边界处为零时的退化行为,导致次级电子平衡不完整和轫致辐射产生被抑制。角分布分析揭示了0 mm PHSP中近前向粒子堆积,而1 mm偏移恢复了大角度次级粒子的缺失。下游1 mm偏移完全缓解了这些伪影,同时对初级束特性引入可忽略的扰动。此要求适用于任何在材料出口表面记录PHSP文件的基于Geant4的框架(包括TOPAS和GATE)。
英文摘要:
Applicator-specific phase space (PHSP) files recorded at the aperture exit reduce Monte Carlo dose calculation time by 30-50% for electron FLASH radiotherapy. However, positioning PHSP scoring planes coincident with the applicator-air interface introduces boundary sampling artifacts. This study characterizes these artifacts in Geant4-based simulations and demonstrates their mitigation. PHSP files were generated using GAMOS 6.2.0 for a 9 MeV Mobetron UHDR model across twelve clinical aperture configurations (2.5-10 cm diameter). Three scoring plane positions were evaluated relative to the physical aperture exit: coincident with the interface, 0.1 mm downstream, and 1 mm downstream. Scoring at the exact interface produced proximal R50 shifts of up to 2.2 mm and Distance-to-Agreement (DTA) values of 4-6 mm, exceeding clinical acceptance criteria. Artifact severity scaled inversely with aperture diameter, with the smallest configurations most severely affected. A 0.1 mm offset partially restored the primary electron energy spectrum but failed to recover the bremsstrahlung tail. A 1 mm offset fully resolved all artifacts, achieving mean DTA values within 2.0 mm, equivalent to or better than linac-exit references. These artifacts arise from the degenerate behavior of the fUseSafety step-limitation algorithm when safety equals zero at exact material boundaries, producing incomplete secondary electron equilibration and suppressed bremsstrahlung production. Angular distribution analysis revealed a near-forward particle pileup in the 0 mm PHSP and a deficit of large-angle secondaries recovered by the 1 mm offset. A 1 mm downstream offset fully mitigates these artifacts while introducing negligible perturbation to primary beam characteristics. This requirement applies to any Geant4-based framework (including TOPAS and GATE) scoring PHSP files at material exit surfaces.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。