Wave-Equation Migration Velocity Analysis for Multistatic Synthetic Aperture Ultrasound
University of Rochester Medical Center(罗切斯特大学医学中心);MIT Lincoln Laboratory(麻省理工学院林肯实验室);University of Rochester(罗切斯特大学);Stanford School of Medicine(斯坦福大学医学院)
Rehman Ali, Trevor M. Mitcham, Marvin M. Doyley, Nebojsa Duric, Jeremy J. Dahl
备注:
12 pages, 7 figures, will be submitted to IEEE Transactions on Ultrasonics for peer review
Sound speed heterogeneities can create aberrations in B-mode ultrasound images by inducing tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. By using the Fourier split-step method to simulate pressure fields in heterogenous sound speed media, reverse-time migration (RTM) can reconstruct the B-mode image by cross-correlating transmitted and received pressure fields. As a result, RTM is differentiable with respect to sound speed. This enables the reconstruction of the sound speed profile that minimizes the aberration in the B-mode image. In seismic imaging, this form of diffraction tomography, known as wave-equation migration velocity analysis, can roughly be understood as a type of full-waveform inversion (FWI) that acts in the image domain rather than errors in the received channel data. This is the first work applying WEMVA to medical pulse-echo ultrasound imaging. Phantom experiments show dramatic improvements in image quality with measured improvements in point target resolution from 1.22$\pm$1.01 to 0.32$\pm$0.07 mm and lesion contrast from 3.05 to 4.39 dB.
Estimating Phase Aberration from Noisy Radiofrequency Data of a single frame of Synthetic Aperture Ultrasound Image
相位差是超声成像中图像退化的主要原因之一。归一化互相关(Normalized-Cross-Correlation,NCC)是目前研究最多的估计到达时延误差和像差分布的方法之一。\textit{However, the performance of NCC can be compromised when the data have a poor signal-to-noise-ratio.}在这里,我们提出了一种迭代滤波NCC(f-NCC)的方法来估计相位畸变的散斑区域从噪声的射频数据的合成发射孔径(STA)图像的单帧。首先,二维滤波器被应用在孔径和时间域中,以抑制来自任意散斑区域的发射波束形成数据中的噪声和离轴信号。其次,采用一种将相位畸变同时包含在发射和接收过程中的迭代方法来估计相位畸变。第三,通过迭代补零技术校正边缘效应,改进了估计。最后,在实验研究中,我们提出并验证了一个公式来估计由声速误差引起的到达时间误差。数值模拟和实验研究的结果都证实了所提出的滤波NCC方法可以从散斑区域的噪声STA RF数据中正确地估计相位像差轮廓。对比度、分辨率和图像信噪比方面的图像质量得到改善。潜在的应用所提出的方法来映射局部速度的样本进行了讨论。
Whole-skull acoustic transparency from a single time-reversal solve for reciprocity-based transducer placement and aperture optimization in transcranial focused ultrasound
Lampe Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University(北卡罗来纳大学教堂山分校与北卡罗来纳州立大学联合兰佩生物医学工程系)
Ultrafast 3-D Super Resolution Ultrasound using Row-Column Array specific Coherence-based Beamforming and Rolling Acoustic Sub-aperture Processing: In Vitro, In Vivo and Clinical Study
On the evaluation of the suitability of the materials used to 3D print holographic acoustic lenses to correct transcranial focused ultrasound aberrations