arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.21173physics.med-ph
收藏

Geant4 PET pipelines中正电子对源的显式建模:受控的双光子和三光子生成与验证

PsSource: an installable Geant4 extension for transport-coupled positronium annihilation with validated Ore-Powell three-photon physics

Indiana University School of Medicine(印第安纳大学医学院)

Jason G Parker

AI总结:

本文在Geant4中实现显式正电子对源模型,实现对湮灭通道选择、衰变时间和光子发射拓扑的事件级控制,并通过实验验证其准确性与效率。

摘要:

本文在Geant4中实现了一个显式正电子对(Ps)源模型,以提供对湮灭通道选择、衰变时间和光子发射拓扑的事件级控制。该实现支持直接湮灭、顺磁正电子对(p-Ps)和反磁正电子对(o-Ps)分支,并允许用户定义各分支的比例,明确将o-Ps事件路由到双光子(2-gamma)或三光子(3-gamma)衰变。该实现支持指数或固定延迟采样,可选的即时光子发射以及可选的正电子范围位移。事件级真实元数据被保留以支持后续的验证和分析。该实现通过受控的Geant4研究进行了评估,使用原生参考配置、显式分支比例扫描、寿命扫描、时间基准测试以及冻结点源下游测试框架。观察到的2-gamma和3-gamma比例遵循请求的控制参数,表现出预期的线性行为,测量的平均延迟与规定的寿命设置具有近一对一的一致性。计算成本与事件数量成线性关系,相对于原生Geant4操作有适度的开销。一个最小的下游验证框架被用来验证纯和混合数据集的一致处理,包括预期的方法-源兼容性和在统一的2-gamma和3-gamma路由下的有效事件恢复。这些结果建立了一个在Geant4中显式正电子对建模的实用且一致的代码框架,并为PET研究人员提供了一条简单路径,将受控的Ps生成纳入现有的模拟管道中。

英文摘要:

PsSource is an installable Geant4 extension for configurable positronium-aware terminal positron annihilation. Geant4 transports the positron normally, after which PsSource replaces only terminal at-rest annihilation, preserves the terminal position and global time, resolves a fixed or host-defined environment, samples the annihilation class and delay, and returns ordinary two- or three-photon secondaries. Supported outcomes are direct two-photon, para-positronium two-photon, ortho-positronium two-photon, and ortho-positronium three-photon annihilation. Fixed and exponential delays and approximate phase-space, Geant4 Ore-Powell, and polarized Geant4 Ore-Powell backends are available. Regression tests verified terminal-state preservation, timing decomposition, all four classes, photon multiplicity and parentage, equivalent environment pathways, and unchanged photon physics when PsSource-specific truth recording was disabled. The Ore-Powell backend was evaluated using 100,000 three-photon events. Comparison with an analytic joint-energy distribution yielded chi-square = 1236.91 for 1274 degrees of freedom, a standardized score of -0.735, and a maximum marginal empirical CDF difference of 0.00208. Ordered photon-energy spectra agreed with native Geant4 and GATE references, with no pairwise empirical CDF difference greater than 0.00452. Photon directions and event-plane normals were isotropic with no detectable Cartesian-axis bias. The polarized backend satisfied normalization and transversality to within 1.5 x 10^-12 and preserved the ordinary Ore-Powell energy spectrum. PsSource provides a validated integration layer for positronium-aware terminal annihilation in Geant4.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑